Key Specification
| Module slot | 2 x supervisor module slots
8 x line card slots 4 x switch fabric module slots 4 x power module slots 2 x fan module slots |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
| System packet forwarding rate | 14300 Mpps | System switching capacity | 19200 Gbps |
| Unit dimensions (W x D x H) | 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.) | Unit weight | 43.55 kg (96.01 lbs, empty chassis with 2 fan modules) |
Features
Modular Core Switch RG-S7810C-X
Compact chassis design with a height of 10 RU improves cabinet space utilization.
Eight line card slots support a wide range of cards that provide various port types, including high-density color optical cards, catering to the diverse needs of small, medium, and large-scale campus deployments.
VSU, Delivering Flexible Networking Capabilities and High Performance
VSU technology virtualizes multiple physical switches into one logical unit with a single IP address to realize unified management, simplifying O&M.
Fast link failover within 50 to 200 milliseconds ensures nonstop transmission of critical services.
Hardware-Level Multi-Protection, Delivering Carrier-Grade Reliability
1+1 Supervisor module Redundancy
1+1 hot standby ensures nonstop switch services.
Dual-Boot Redundancy
Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.
N+M Power Supply Redundancy
1+1 hot standby ensures nonstop switch services.
1+1 Fan Module Redundancy
Two axial flow fans for factory delivery support 256-level speed regulation and precise temperature control, reducing energy consumption and noise.
Ruijie Unified Networking Central (RG-UNC) Visualized Management, Automated and Effortless Operations
RG-UNC, a unified visual management platform, supports real-time monitoring of key devices and links, fine-grained alarms, centralized configuration backup and recovery, network-wide management, plug-and-play, and rapid deployment, enhancing O&M efficiency.
Specifications
Hardware Specifications (with -CM Series Supervisor Module)
| Port specifications | RG-S7805C | RG-S7808C | RG-S7810C |
| Module slot | 2 x supervisor module slots
3 x line card slots 2 x power module slots 1 x fan module slot |
2 x supervisor module slots
6 x line card slots 4 x power module slots 2 x fan module slots |
2 x supervisor module slots
8 x line card slots (slot 7 does not support the EB line card) 2 x switch fabric module slots 4 x power module slots 2 x fan module slots |
| Supervisor module | M7805C-CM II | M7808C-CM II | M7810C-CM
M7810C-CM-F |
| Switch fabric module | / | M7808C-CM II (switch fabric module integrated with supervisor module) | M7810C-FE-D I (must be used with M7810C-CM)
M7810C-FE-F I (must be used with M7810C-CM-F) M7810C-CM, M7810C-CM-F (switch fabric module integrated with supervisor module) |
| line card | M7805C-CM II supports the following 9 modules:
● M7800C-32XS4QXS-DA ● M7800C-24GT24SFP4XS-EB ● M7800C-24SFP/12GT4XS-EB ● M7800C-48GT4XS-EB ● M7800C-48SFP4XS-EB ● M7800C-48GT-FA ● M7800C-48SFP-FA ● M7800C-48XS-FB ● M7800C-8CQ-FB *1 |
M7808C-CM II supports the following 9 modules:
● M7800C-32XS4QXS-DA ● M7800C-24GT24SFP4XS-EB ● M7800C-24SFP/12GT4XS-EB ● M7800C-48GT4XS-EB ● M7800C-48SFP4XS-EB ● M7800C-48GT-FA ● M7800C-48SFP-FA ● M7800C-48XS-FB ● M7800C-8CQ-FB *1 |
M7810C-CM supports the following 5 modules:
● M7800C-32XS4QXS-DA ● M7800C-24GT24SFP4XS-EB ● M7800C-24SFP/12GT4XS-EB ● M7800C-48GT4XS-EB ● M7800C-48SFP4XS-EB M7810C-CM-F supports the following 4 modules: ● M7800C-48GT-FA ● M7800C-48SFP-FA ● M7800C-48XS-FB ● M7800C-8CQ-FB *1 |
| Power module | RG-PA300I-F
RG-PA460I-F RG-PA1000I-F |
RG-PA600I-F
RG-PA1600I-F |
RG-PA600I
RG-PA1600I |
| Fan module | M05C-FAN (pre-installed 1) | M08-FAN (pre-installed 2) | M10C-FAN (pre-installed 2) |
| Module management port | M7805C-CM II:
● 1 x RJ45 console port ● 1 x RJ45 MGMT port |
M7808C-CM II:
● 1 x RJ45 console port ● 1 x RJ45 MGMT port |
M7810C-CM:
● 1 x RJ45 console port ● 1 x RJ45 MGMT port M7810C-CM-F: ● 1 x RJ45 console port *2 ● 1 x mini USB console port *2 ● 1 x RJ45 MGMT port |
| USB | M7805C-CM II: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7808C-CM II: 2 x USB 2.0 ports (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7810C-CM: 1 x USB 2.0 port
M7810C-CM-F: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) |
*1 Note: FA/FB series cannot be used with EB series or DA series.
*2 Note: Only one console port is allowed to be used at the same time. The mini USB console port has a higher priority.
| System specifications | RG-S7805C | RG-S7808C | RG-S7810C |
| System packet forwarding rate *3 | 4500 Mpps | 9000 Mpps | 12000 Mpps |
| System switching capacity *4 | 6000 Gbps | 12000 Gbps | 16000 Gbps |
| CPU | Supervisor module:
● M7805C-CM II: quad-core CPU, each core with the clock speed of 1.0 GHz Line card ● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz ● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz |
Supervisor module:
● M7808C-CM II: quad-core CPU, each core with the clock speed of 1.5 GHz Line card ● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz ● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz |
Supervisor module:
● M7810C-CM, M7810C-CM-F: quad-core CPU, each core with the clock speed of 1.5 GHz Line card ● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz ● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz Switch fabric module ● M7810C-FE-D I, M7810C-FE-F I: quad-core CPU, each core with the clock speed of 1.5 GHz |
| Real-time clock (RTC) | M7805C-CM II: supported | M7808C-CM II: supported | M7810C-CM/M7810C-CM-F: supported |
| BootROM | M7805C-CM II:8 MB
EB card: 8 MB DA/FA/FB card: 16 MB |
M7808C-CM II: 16 MB
EB card: 8 MB DA/FA/FB card: 16 MB |
M7810C-CM/M7810C-CM-F: 16 MB
EB card: 8 MB DA/FA/FB card: 16 MB M7810C-FE-D I/M7810C-FE-F I: 16 MB |
| Flash memory | M7805C-CM II: 1 GB
EB card: 512 MB DA/FA/FB card: 8 GB |
M7808C-CM II: 8 GB
EB card: 512 MB DA/FA/FB card: 8 GB |
M7810C-CM/M7810C-CM-F: 8 GB
EB card: 512 MB DA/FA/FB card: 8 GB M7810C-FE-D I/M7810C-FE-F I: 8 GB |
| Memory | M7805C-CM II: 4 GB DDR3
EB card: 1 GB DDR3 DA card: 1 GB DDR4 FA/FB card: 2 GB DDR4 |
M7808C-CM II: 4 GB DDR4
EB card: 1 GB DDR3 DA card: 1 GB DDR4 FA/FB card: 2 GB DDR4 |
M7810C-CM/M7810C-CM-F: 4 GB DDR4
EB card: 1 GB DDR3 DA card: 1 GB DDR4 FA/FB card: 2 GB DDR4 M7810C-FE-D I: 1 GB DDR4 M7810C-FE-F I: 2 GB DDR4 |
| Switch buffer | EB: 4 MB
FB: 32 MB FA: 8 MB DA: 16 MB |
EB: 4 MB
FB: 32 MB FA: 8 MB DA: 16 MB |
EB: 4 MB
FB: 32 MB FA: 8 MB DA: 16 MB |
*3 means the system’s packet forwarding rate.
*4 means the system’s switching capacity.
| Power supply and consumption | RG-S7805C | RG-S7808C | RG-S7810C |
| Power supply | 2 x pluggable power modules | 4 x pluggable power modules | 4 x pluggable power modules |
| Power input | RG-PA300I-F (AC input):
● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 5 A RG-PA460I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz ● Maximum input current: 6 A RG-PA1000I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 10 A |
RG-PA600I-F (AC input):
● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 10 A RG-PA1600I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 16 A |
RG-PA600I (AC input):
● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 8 A RG-PA1600I (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 16 A |
| Maximum output power | RG-PA300I-F: 300 W
RG-PA460I-F: 460 W RG-PA1000I-F: ● 100 V AC to 176 V AC: 800 W ● 176 V AC to 240 V AC: 1000 W |
RG-PA600I-F: 600 W
RG-PA1600I-F: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W |
RG-PA600I: 600 W
RG-PA1600I: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W |
| Module power consumption | M05C-FAN: < 80 W
M7805C-CM II: < 21 W |
M08-FAN: < 88 W
M7808C-CM II: < 50 W |
M10C-FAN: < 216 W
M7810C-CM: < 50 W M7810C-CM-F: < 110 W |
| M7800C-32XS4QXS-DA: < 210 W
M7800C-24GT24SFP4XS-EB: < 88 W M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-8CQ-FB: < 130 W |
|||
| Dimensions and Weight | RG-S7805C | RG-S7808C | RG-S7810C |
| Unit dimensions (W x D x H) | 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.) | 442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) | 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.) |
| Shipping dimensions (W x D x H) | 750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.) | 710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.) | 845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.) |
| Rack height | 4 RU | 10 RU | 10 RU |
| Unit weight | 12.42 kg (27.38 lbs, empty chassis with 1 fan module) | 35.60 kg (78.48 lbs, empty chassis with 2 fan modules) | 43.60 kg (96.01 lbs, empty chassis with 2 fan modules) |
| Shipping weight | 28.05 kg (61.84 lbs) | 43.93 kg (96.85 lbs) | 68.30 kg (150.58 lbs) |
| Environment and reliability | RG-S7805C | RG-S7808C | RG-S7810C |
| Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F) |
||
| Humidity | Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing) |
||
| Altitude | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)
Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) |
||
| Mean time between failure (MTBF) | 216,000 hours (about 24 years) | 216,000 hours (about 24 years) | 342,000 hours (about 39 years) |
| Fan | 1 x pluggable fan module (pre-installed) | 2 x pluggable fan modules (pre-installed) | 2 x pluggable fan modules (pre-installed) |
| Heat dissipation | Supervisor module: right-to-left airflow
Line card: right-to-rear airflow Power module: built-in fan modules drawing air outward, front-to-rear airflow |
Supervisor module: right-to-rear airflow
Line card: right-to-rear airflow Power module: front-to-rear airflow |
Supervisor module: front-to-rear airflow
Line card: side-to-rear airflow FE card: front-to-rear airflow |
| Acoustic noise | 27°C (80.6°F): 70 dB
Max Noise: 77 dB |
27°C (80.6°F): 70 dB
Max Noise: 77 dB |
27°C (80.6°F): 70 dB
Max Noise: 77 dB |
| Supervisor module redundancy | 1+1 redundancy | 1+1 redundancy | 1+1 redundancy (same model) |
| Power module redundancy | 1+1 redundancy (same model) | N+M redundancy (same model) | N+M redundancy (same model) |
| Fan redundancy | Not supported | 1+1 redundancy | 1+1 redundancy |
| Module hot swapping | Supported | Supported | Supported |
| Power module hot swapping | Supported | Supported | Supported |
| Fan module hot swapping | Supported | Supported | Supported |
| Cable hot swapping | All ports on line cards support hot swapping of cables.
The switch-mode power supply supports hot swapping of power cords. |
||
| Power supply monitoring | Monitoring of the model, temperature, power, and voltage of the power supply module
Power supply failure alarming Control of line card power-on based on the power supply status |
||
| Fan monitoring | Fan speed adjustment: 256 levels
Fan failure alarming |
||
| Temperature monitoring | Over-temperature alarming | ||
| ESD | ESD contact/air discharge: 6 kV/8 kV
ESD susceptibility contact/air discharge: 8 kV/15 kV |
||
| Surge protection | MGMT port: 4 kV
Service port: 4 kV Power port: 6 kV |
||
| Certifications and regulatory compliance | RG-S7805C | RG-S7808C | RG-S7810C |
| Safety regulation | IEC 62368-1 | ||
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035,
EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
||
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 | ||
Hardware Specifications (with -X Series Supervisor Module)
| Port specifications | RG-S7805C | RG-S7808C | RG-S7810C-X |
| Module slot | 2 x supervisor module slots
3 x line card slots 2 x power module slots 1 x fan module slot |
2 x supervisor module slots
6 x line card slots 4 x power module slots 2 x fan module slots |
2 x supervisor module slots
8 x line card slots 4 x switch fabric module slots 4 x power module slots 2 x fan module slots |
| Supervisor module | M7805C-CM-X | M7808C-CM-X | M7810C-CM-X |
| Switch fabric module | / | M7808C-CM-X (switch fabric module integrated with supervisor module) | M7810C-FE-X I
M7810C-FE-X II |
| line card | M7800C-48GT4XS-XA
M7800C-48SFP4XS-XA M7800C-24GT8SFP8XS-XA M7800C-32XS-XA M7800C-52XS-XB M7800C-12CQ-XB M7800C-48XT-P-XB |
M7800C-48GT4XS-XA
M7800C-48SFP4XS-XA M7800C-24GT8SFP8XS-XA M7800C-32XS-XA M7800C-52XS-XB M7800C-12CQ-XB M7800C-48XT-P-XB M7800C-8SFG-XB M7800C-8SFX-XB |
M7800C-48GT4XS-XA
M7800C-48SFP4XS-XA M7800C-24GT8SFP8XS-XA M7800C-32XS-XA M7800C-52XS-XB M7800C-12CQ-XB M7800C-48XT-P-XB M7800C-8SFG-XB M7800C-8SFX-XB |
| Power module | RG-PA300I-F
RG-PA460I-F RG-PA1000I-F |
RG-PA600I-F
RG-PA1600I-F |
RG-PA600I
RG-PA1600I RG-PD600I |
| Fan module | M05C-FAN (pre-installed 1) | M08-FAN (pre-installed 2) | M10C-FAN (pre-installed 2) |
| Module management port | M7805C-CM-X:
● 1 x RJ45 console port ● 1 x RJ45 MGMT port |
M7808C-CM-X:
● 1 x RJ45 console port ● 1 x RJ45 MGMT port |
M7810C-CM-X:
● 1 x RJ45 console port ● 1 x RJ45 MGMT port M7810C-FE-X I/II: ● 1 x RJ45 console port |
| USB | M7805C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7808C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) | M7810C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) |
| System specifications | RG-S7805C | RG-S7808C | RG-S7810C-X |
| System packet forwarding rate *3 | 4500 Mpps | 9000 Mpps | 14300 Mpps |
| System switching capacity *4 | 6000 Gbps | 12000 Gbps | 19200 Gbps |
| CPU | Supervisor module:
● M7805C-CM-X: quad-core processor, each core 2.2 GHz Line card: ● XA/XB series line card: quad-core processor, each core 2.2 GHz |
Supervisor module:
● M7808C-CM-X: quad-core processor, each core 2.2 GHz Line card: ● XA/XB series line card: quad-core processor, each core 2.2 GHz |
Supervisor module:
● M7810C-CM-X: quad-core processor, each core 2.2 GHz Line card: ● XA/XB series line card: quad-core processor, each core 2.2 GHz |
| Real-time clock (RTC) | M7805C-CM-X: supported | M7808C-CM-X: supported | M7810C-CM-X: supported |
| BootROM | M7805C-CM-X: 16 MB
XA/XB card: 16 MB |
M7808C-CM-X: 16 MB
XA/XB card: 16 MB |
M7810C-CM-X: 16 MB
M7810C-FE-X I/II: 16 MB XA/XB card: 16 MB |
| Flash memory | M7805C-CM-X: 8 GB
XA/XB card: 8 GB |
M7808C-CM-X: 8 GB
XA/XB card: 8 GB |
M7810C-CM-X: 8 GB
M7810C-FE-X I/II: 8 GB XA/XB card: 8 GB |
| Memory | M7805C-CM-X: 4 GB DDR4
XA/XB card: 4 GB DDR4 |
M7808C-CM-X: 4 GB DDR4
XA/XB card: 4 GB DDR4 |
M7810C-CM-X: 4 GB DDR4
M7810C-FE-X I: 1 GB DDR4 M7810C-FE-X II: 4 GB DDR4 XA/XB card: 4 GB DDR4 |
| Switch buffer | XA series line card (excluding M7800C-32XS-XA): 4 MB
XB series line card: 35 MB M7800C-32XS-XA: 35 MB |
XA series line card (excluding M7800C-32XS-XA): 4 MB
XB series line card: 35 MB M7800C-32XS-XA: 35 MB |
XA series line card (excluding M7800C-32XS-XA): 4 MB
XB series line card: 35 MB M7800C-32XS-XA: 35 MB |
*3 means the system’s packet forwarding rate.
*4 means the system’s switching capacity.
| Power supply and consumption | RG-S7805C | RG-S7808C | RG-S7810C-X |
| Power supply | 2 x pluggable power modules | 4 x pluggable power modules | 4 x pluggable power modules |
| Power input | RG-PA300I-F (AC input):
● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 5 A RG-PA460I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz ● Maximum input current: 6 A RG-PA1000I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 10 A |
RG-PA600I-F (AC input):
● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 10 A RG-PA1600I-F (AC input): ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 16 A |
RG-PA600I (AC input):
● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz ● Maximum input current: 8 A RG-PA1600I (AC input): ● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 16 A RG-PD600I (DC input): ● Rated input voltage: –48 V DC ● Maximum input voltage: –40 V DC to –75 V DC ● Maximum input current: 20 A |
| Maximum output power | RG-PA300I-F: 300 W
RG-PA460I-F: 460 W RG-PA1000I-F: ● 100 V AC to 176 V AC: 800 W ● 176 V AC to 240 V AC: 1000 W |
RG-PA600I-F: 600 W
RG-PA1600I-F: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W |
RG-PA600I: 600 W
RG-PA1600I: ● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W RG-PD600I: 600 W |
| Module power consumption | M05C-FAN: < 80 W
M7805C-CM-X: < 40 W |
M08-FAN: < 88 W
M7808C-CM-X: < 62 W
M7800C-8SFG-XB: < 250 W M7800C-8SFX-XB: < 250 W |
M10C-FAN: < 216 W
M7810C-CM-X: < 60 W M7810C-FE-X I: < 50 W M7810C-FE-X II: < 160 W M7800C-8SFG-XB: < 250 W M7800C-8SFX-XB: < 250 W |
| M7800C-48GT4XS-XA: < 85 W
M7800C-48SFP4XS-XA: < 117 W M7800C-24GT8SFP8XS-XA: < 95 W M7800C-32XS-XA: < 149 W M7800C-52XS-XB: < 250 W M7800C-12CQ-XB: < 240 W M7800C-48XT-P-XB: < 300 W |
|||
If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB.
| Hardware Specifications | M78-PSE-X |
| Fixed service port | 2 x PoE out ports |
| Module slot | 2 x power module slots |
| Power module | RG-PA1600I-PL |
| Power supply | 2 x pluggable power modules |
| Power input | RG-PA1600I-PL (AC input):
● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz ● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz ● Maximum input current: 16 A |
| Maximum output power | RG-PA1600I-PL
● 100 V AC to 176 V AC: 1200 W ● 176 V AC to 240 V AC: 1600 W |
| PoE output power | Each PoE out port provides up to 1,440 W of power |
| Unit dimensions (W x D x H) | 400.0 mm x 420.0 mm x 44.7 mm (15.75 in. x 16.54 in. x 1.76 in.) |
| Unit weight | 5.0 kg (11.02 lbs) |
| Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F) Storage temperature: –40°C to +70°C (–40°F to +158°F) |
| Humidity | Operating humidity: 10% to 90% RH (non-condensing) Storage humidity: 5% to 95% RH (non-condensing) |
| Mean time between failure (MTBF) | 4,289,000 hours (about 489 years) |
| Power module redundancy | 1+1 redundancy (same model) |
| Dimensions and Weight | RG-S7805C | RG-S7808C | RG-S7810C-X |
| Unit dimensions (W x D x H) | 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.) | 442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) | 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.) |
| Shipping dimensions (W x D x H) | 750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.) | 710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.) | 845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.) |
| Rack height | 4 RU | 10 RU | 10 RU |
| Unit weight | 12.42 kg (27.38 lbs, empty chassis with 1 fan module) | 35.6 kg (78.48 lbs, empty chassis with 2 fan modules) | 43.55 kg (96.01 lbs, empty chassis with 2 fan modules) |
| Shipping weight | 28.05 kg (61.84 lbs) | 43.93 kg (96.85 lbs) | 68.30 kg (150.58 lbs) |
| Environment and reliability | RG-S7805C | RG-S7808C | RG-S7810C-X |
| Temperature | Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F) |
||
| Humidity | Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing) |
||
| Altitude | Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)
Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.) |
||
| Mean time between failure (MTBF) | 216,000 hours (about 24 years) | 216,000 hours (about 24 years) | 342,000 hours (about 39 years) |
| Fan | 1 x pluggable fan module (pre-installed) | 2 x pluggable fan modules (pre-installed) | 2 x pluggable fan modules (pre-installed) |
| Heat dissipation | Supervisor module: right-to-left airflow
Line card: right-to-rear airflow Power module: built-in fan modules drawing air outward, front-to-rear airflow |
Supervisor module: right-to-rear airflow
Line card: right-to-rear airflow Power module: front-to-rear airflow |
Supervisor module: front-to-rear airflow
Line card: side-to-rear airflow FE card: front-to-rear airflow |
| Acoustic noise | 27°C (80.6°F): 70 dB
Max Noise: 77 dB |
27°C (80.6°F): 70 dB
Max Noise: 77 dB |
27°C (80.6°F): 70 dB
Max Noise: 77 dB |
| Supervisor module redundancy | 1+1 redundancy | 1+1 redundancy | 1+1 redundancy |
| Power module redundancy | 1+1 redundancy (same model) | N+M redundancy (same model) | N+M redundancy (same model) |
| Fan redundancy | Not supported | 1+1 redundancy | 1+1 redundancy |
| Module hot swapping | Supported | Supported | Supported |
| Power module hot swapping | Supported | Supported | Supported |
| Fan module hot swapping | Supported | Supported | Supported |
| Cable hot swapping | All ports on line cards support hot swapping of cables.
The switch-mode power supply supports hot swapping of power cords. |
||
| Power supply monitoring | Monitoring of the model, temperature, power, and voltage of the power supply module
Power supply failure alarming Control of line card power-on based on the power status |
||
| Fan monitoring | Fan speed adjustment: 256 levels
Fan failure alarming |
||
| Temperature monitoring | Over-temperature warning | ||
| ESD | ESD contact/air discharge: 6 kV/8 kV
ESD susceptibility contact/air discharge: 8 kV/15 kV |
||
| Surge protection | MGMT port: 4 kV
Service port: 4 kV Power port: 6 kV |
||
| Certifications and regulatory compliance | RG-S7805C | RG-S7808C | RG-S7810C-X |
| Safety regulation | IEC 62368-1 | ||
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035,
EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
||
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 | ||
Software Specifications (with -CM Series Supervisor Module)
| Feature | RG-S7800C Series |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| 802.3az EEE | |
| Maximum number of VLANs that can be created: 4,094 | |
| Voice VLAN | |
| Super-VLAN and private VLAN | |
| MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment | |
| GVRP | |
| Basic QinQ and selective QinQ | |
| STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) | |
| ERPS (G.8032) | |
| LLDP/LLDP-MED | |
| IP service | Static and dynamic ARP |
| DHCP client | |
| DHCP relay | |
| DHCP server | |
| DHCP snooping | |
| DNS | |
| DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping | |
| Neighbor Discovery (ND) and ND snooping | |
| Manual tunnel, automatic tunnel, and ISATAP tunnel for IPv6 | |
| GRE tunnel | |
| IP routing | Static routing |
| RIP and RIPng | |
| OSPFv2 and OSPFv3 | |
| GR | |
| IPv4/IPv6 IS-IS | |
| BGP4 and BGP4+ | |
| EVPN | |
| IPv4/IPv6 VRF | |
| Policy-based routing (PBR) | |
| IPv4 and IPv6 ECMP | |
| Multicast | IGMP v1/v2/v3 |
| IGMP snooping v1/v2/v3 | |
| IGMP proxy | |
| IGMP fast leave | |
| PIM-DM, PIM-SM, and PIM-SSM | |
| PIM-SSM for IPv4 and IPv6 | |
| MSDP to achieve inter-domain multicast | |
| MLDv1 and MLDv2 | |
| Multicast static routing | |
| MLD v1/v2 snooping | |
| PIM-SMv6 | |
| Multicast source IP address check
Multicast source port check |
|
| MPLS | MPLS IPv6 |
| MPLS L3VPN | |
| MPLS 6VPE | |
| MPLS MIB (RFC 1273, RFC 4265, and RFC 4382) | |
| ACL and QoS | Standard IP ACLs (hardware ACLs based on IP addresses) |
| Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers) | |
| Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type) | |
| Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) | |
| ACL80 and IPv6 ACL | |
| Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range) | |
| ACL redirection | |
| Port traffic identification | |
| Port-based rate limiting | |
| 802.1p | |
| Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences | |
| CAR | |
| Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ | |
| Congestion avoidance: tail drop, RED, and WRED | |
| Eight queues on each port | |
| Security | AAA |
| RADIUS authorization and accounting | |
| TACACS+ | |
| Portal authentication, RADIUS, and TACACS+ login authentication | |
| IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication | |
| Web authentication | |
| Hypertext Transfer Protocol Secure (HTTPS) | |
| SSHv1 and SSHv2 | |
| Global IP-MAC binding | |
| ICMP | |
| Port security | |
| IP source guard | |
| DAI | |
| SAVI | |
| ARP spoofing prevention | |
| CPU Protect Policy (CPP) and NFPP | |
| Various attack defense functions, including NFPP and ARP anti-attack | |
| uRPF
Login authentication and password security Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed. |
|
| Reliability | Rapid Ethernet Uplink Protection (REUP) |
| Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control | |
| Data Link Detection Protocol (DLDP) | |
| IPv4 VRRP v2/v3 and IPv6 VRRP | |
| VRRP for the super-VLAN | |
| BFD | |
| RG-S7805C, RG-S7808C , RG-S7810C: 1+1 redundancy for supervisor modules | |
| RG-S7805C: 1+1 redundancy for power supply
RG-S7808C , RG-S7810C: N+M redundancy for power supply |
|
| RG-S7805C: fan redundancy is not supported
RG-S7808C , RG-S7810C: 1+1 fan redundancy |
|
| Hot swapping of components | |
| Hot patch and online installation of patches | |
| GR for OSPF/IS-IS/BGP | |
| BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing | |
| Device virtualization | VSU |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| sFlow | |
| NTP | |
| SNTP | |
| FTP, TFTP, and Xmodem | |
| SNMP v1/v2c/v3 | |
| RMON (1, 2, 3, 9) | |
| NETCONF | |
| CWMP | |
| gRPC | |
| OpenFlow Special 1.3
Flow table analysis defined by all protocols Transmission of specified packets to the controller Configuring the controller’s IP address and port Notifying port status changes to the controller |
|
| Web-based NMS | |
| Console/Telnet/SSH2.0 CLI configuration
Fault alarms and auto-recovery System operation logging |
|
| VXLAN | Layer 2 and Layer 3 VXLAN gateways |
Software Specifications (with -X Series Supervisor Module)
| Software Specifications | RG-S7800C-X Series |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| 802.3az EEE | |
| Maximum number of VLANs that can be created: 4,094 | |
| Voice VLAN | |
| GVRP | |
| IP subnet-based VLAN | |
| MAC VLAN | |
| Port-based VLAN | |
| Private VLAN | |
| protocol-based VLAN | |
| Super-VLAN | |
| Basic QinQ and selective QinQ | |
| STP (IEEE 802.1.d) | |
| RSTP (IEEE 802.1w) | |
| MSTP (IEEE 802.1s) | |
| ERPS (G.8032) | |
| LLDP/LLDP-MED | |
| Device Virtualization | VSU |
| SDN | OpenFlow 1.3
NETCONF |
| IP service | Static and dynamic ARP |
| DHCP client | |
| DHCP relay | |
| DHCP server | |
| DHCP snooping | |
| DNS | |
| DHCPv6 client | |
| DHCPv6 relay | |
| DHCPv6 snooping | |
| Neighbor Discovery (ND) and ND snooping | |
| FTP Server | |
| FTP Client | |
| NTP server | |
| NTP Client | |
| SNTP Client | |
| TFTP Client | |
| TFTP Server | |
| IP routing | Static routing |
| BGP4 | |
| BGP4+ | |
| IS-ISv4 | |
| IS-ISv6 | |
| OSPFv2 | |
| OSPFv3 | |
| RIP | |
| RIPng | |
| GR | |
| Routing Policy | |
| ECMP | |
| IPv4/IPv6 VRF | |
| Policy-based routing (PBR) | |
| Multicast | IGMP v1/v2/v3 |
| IGMP snooping v1/v2 | |
| IGMP proxy | |
| IGMP fast leave | |
| PIM-DM | |
| PIM-SM | |
| PIM-SSM for IPv4 and IPv6 | |
| MSDP to achieve inter-domain multicast | |
| MLDv1 and MLDv2 | |
| Multicast static routing | |
| MLD v1/v2 snooping | |
| PIM-SMv6 | |
| Multicast source IP address check | |
| Multicast source port check | |
| MPLS | MPLS L3VPN |
| MPLS 6VPE | |
| MPLS IPv6 | |
| MPLS forwarding | |
| LDP | |
| LSP | |
| VXLAN | VXLAN Layer 2 bridge |
| VXLAN Layer 3 gateway | |
| EVPN VXLAN | |
| ACL and QoS
|
Standard IP ACL |
| extended IP ACL | |
| extended MAC ACL | |
| Layer 2 and Layer 3 port ACL | |
| VLAN ACL | |
| Expert-level ACL | |
| ACL 80 | |
| IPv6 ACL | |
| Applying ACLs globally | |
| ACL COUNTER | |
| ACL LOGGING | |
| ACL REMARK | |
| 802.1P | |
| SP | |
| WRR | |
| SP+WFR | |
| other queue scheduling mechanisms | |
| RED/WRED | |
| Rate limiting based on the inbound or outbound interface | |
| MPLS QOS | |
| Reliability | RG-S7805C, RG-S7808C , RG-S7810C-X: 1+1 redundancy for supervisor modules |
| RG-S7805C: 1+1 redundancy for power supply
RG-S7808C , RG-S7810C-X: N+M redundancy for power supply |
|
| RG-S7805C: fan redundancy is not supported
RG-S7808C , RG-S7810C-X: 1+1 fan redundancy |
|
| Hot swapping of all components | |
| Hot patching function for online patch upgrade | |
| GR | |
| BFD | |
| VRRP | |
| VRRP+ | |
| Faulty optical port isolation | |
| Dual physical chips for boot systems | |
| Security | NFPP |
| CPP | |
| DAI | |
| port security | |
| IP source guard | |
| 802.1X authentication | |
| MAC address-based authentication | |
| Portal authentication | |
| RADIUS | |
| TACACS+ login authentication | |
| uRPF | |
| SSHv2 | |
| IPv6 SAVI | |
| Login authentication and password security | |
| providing encrypted security channels for user login | |
| Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed. | |
| NMS and maintenance | Console/AUX Modem/Telnet/SSH2.0 CLI configuration |
| File upload and download management using FTP, TFTP, and Xmodem | |
| SNMP V1/V2c/V3 | |
| RMON | |
| CWMP | |
| GRPC | |
| Fault alarm and auto-recovery | |
| System operation logging | |
| sFlow | |
| SPAN | |
| RSPAN | |
| ERSPAN | |
| VLAN mirroring | |
| Web-based NMS | |
| Energy-Saving Design | IEEE 802.3az Energy Efficient Ethernet |
Order Information
Switch Chassis
| Model | Description |
| RG-S7805C | RG-S7805C switch, which can accommodate three line cards and two supervisor modules (supporting -CM series and -X series supervisor modules) |
| RG-S7808C | RG-S7808C switch, which can accommodate six line cards and two supervisor modules (supporting -CM series and -X series supervisor modules) |
| RG-S7810C | RG-S7810C switch, which can accommodate eight service cards, two supervisor modules, and two switch fabric modules (supporting -CM series supervisor modules) |
| RG-S7810C-X | RG-S7810C-X switch, which can accommodate eight line cards, two supervisor modules, and four switch fabric modules (supporting -X series supervisor modules) |
Supervisor Modules
| Model | Description |
| M7805C-CM II | S7805C high-performance 2nd-generation supervisor module |
| M7808C-CM II | S7808C high-performance 2nd-generation supervisor module |
| M7810C-CM | S7810C high-performance 1st-generation supervisor module |
| M7810C-CM-F | S7810C high-performance 2nd-generation supervisor module |
| M7805C-CM-X | RG-S7805C high-performance supervisor module |
| M7808C-CM-X | RG-S7808C high-performance supervisor module |
| M7810C-CM-X | RG-S7810C-X high-performance supervisor module |
Notes:
- Different models cannot be interchanged.
- Mandatory item, 1+1 redundancy supported, and at least one supervisor module must be configured.
Switch Fabric Modules
| Model | Description |
| M7810C-FE-D I | RG-S7810C switch fabric module I |
| M7810C-FE-F I | RG-S7810C 2nd-generation switch fabric module |
| M7810C-FE-X I | RG-S7810C-X 1st-generation switch fabric module |
| M7810C-FE-X II | RG-S7810C-X 2nd-generation switch fabric module |
Line Cards
Working with -CM series supervisor module
| Model | Description |
| M7800C-32XS4QXS-DA | 32 x 1GE/10GE SFP+ ports (LC) and 4 x 40GE QSFP+ ports (MPO), supporting splitting a 40GE port into 4 x 10GE optical ports |
| M7800C-24GT24SFP4XS-EB | 24 x 10/100/1000BASE-T ports (RJ45), 24 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC) |
| M7800C-24SFP/12GT4XS-EB | 24 x 100M/1GE SFP ports (LC), 12 x 10/100/1000BASE-T combo ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC) |
| M7800C-48GT4XS-EB | 48 x 10/100/1000BASE-T ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC) |
| M7800C-48SFP4XS-EB | 48 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC) |
| M7800C-48GT-FA | 48 x 10/100/1000BASE-T ports (RJ45) |
| M7800C-48SFP-FA | 48 x 100M/1GE SFP ports (LC) |
| M7800C-48XS-FB | 48 x 1GE/10GE SFP+ ports (LC) |
| M7800C-8CQ-FB | 8 x 40GE/100GE QSFP28 ports (LC) |
Notes:
- EB series line cards only interchanged with DA series line cards.
- DA series line cards only interchanged with EB series line cards.
- FA/FB series line cards cannot be interchanged with EB/DA series line cards.
Working with -X series supervisor module
| Model | Description |
| M7800C-48GT4XS-XA | 48 x 10/100/1000BASE-T ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC) |
| M7800C-48SFP4XS-XA | 48 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC) |
| M7800C-24GT8SFP8XS-XA | 24 x 10/100/1000BASE-T ports (RJ45), 8 x 100M/1GE SFP ports (LC) and 8 x 1GE/10GE SFP+ ports (LC) |
| M7800C-32XS-XA | 32 x 1GE/10GE SFP+ ports (LC) |
| M7800C-52XS-XB | 52 x 1GE/10GE SFP+ ports (LC) |
| M7800C-12CQ-XB | 12 x 40GE/100GE QSFP28 ports (MPO/LC). One 100GE port can be split into four 25GE ports and one 40GE port can be split into four 10GE ports. |
| M7800C-48XT-P-XB | 48 x 100/1000/2.5G/5G/10GBASE-T ports (RJ45), supporting PoE/PoE+. Each PoE port provides up to 30 W of power. The maximum power is 1440 W over 48 ports (30 W x 48).
1 x PoE in port receives PoE/PoE+ power supply. If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB. |
| M7800C-8SFG-XB | 8 x SFG ports (64 x 1GE logical channels). CWDM line card for RG-S7810C-X and RG-S7808C (used with the M7808C-CM-X supervisor module) |
| M7800C-8SFX-XB | 8 x SFX ports (64 x 10GE logical channels) with each port backward compatible with the Gigabit rate. CWDM line card for RG-S7810C-X and RG-S7808C (used with the M7808C-CM-X supervisor module) |
Power Chassis and Modules
| Model | Description |
| RG-PA300I-F | 300 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C |
| RG-PA460I-F | 460 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C |
| RG-PA600I | 600 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7810C & RG-S7810C-X |
| RG-PA600I-F | 600 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7808C |
| RG-PA1000I-F | 1000 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C |
| RG-PA1600I | 1600 W AC power module, supporting redundancy, 16 A power cord, used with RG-S7810C & RG-S7810C-X |
| RG-PA1600I-F | 1600 W AC power module, supporting redundancy, 16 A power cord, used with RG-S7808C |
| M78-PSE-X | PoE power chassis. 2 x PoE out ports can power two PoE line cards through specialized PoE cables. 2 x power module slots, used together with RG-PA1600I-PL (working with -X series supervisor module) |
| RG-PA1600I-PL | 1600 W PoE AC power module, supporting redundancy, 16 A power cord, used with M78-PSE-X (working with -X series supervisor module) |
| RG-PD600I | 600 W DC power module, supporting redundancy, 20 A power cord, used with RG-S7810C-X |
Optical Transceivers and Cables
1GE
| Model | Description |
| Mini-GBIC-GT | 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a
The port needs to be configured with auto-negotiation |
| MINI-GBIC-SX-MM850 | 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
| MINI-GBIC-LX-SM1310 | 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| MINI-GBIC-LH40-SM1310 | 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
| MINI-GBIC-ZX80-SM1550 | 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF |
| GE-SFP-LX20-SM1550-BIDI | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF |
| GE-SFP-LH40-SM1310-BIDI | 1000BASE-LH, SFP transceiver, TX1310/RX1550, BiDi LC, 40 km over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1000BASE-LH, SFP transceiver, TX1550/RX1310, BiDi LC, 40 km over SMF |
| GE-SFP-LX03-SM1310-BIDI-I | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF |
| GE-SFP-LX03-SM1550-BIDI-I | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF |
Note: BiDi transceivers must be used in pairs. If one end uses GE-SFP-LX20-SM1310-BIDI, the other end must use GE-SFP-LX20-SM1550-BIDI.
10GE
| Model | Description |
| XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
| XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
| XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
| XG-SFP-ZR-SM1550 | 10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF |
| XG-SFP-LR10-SM1270-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF |
| XG-SFP-LR10-SM1330-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF |
| XG-SFP-AOC1M | 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
| XG-SFP-AOC3M | 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
| XG-SFP-AOC5M | 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
Note: BiDi transceivers must be used in pairs. If one end uses XG-SFP-LR10-SM1270-BIDI-I, the other end must use XG-SFP-LR10-SM1330-BIDI-I.
40GE
| Model | Description |
| 40G-QSFP-LSR-MM850 | 40GBASE-LSR, QSFP+ transceiver, 850 nm, MPO 1 x 12, 400 m over OM4 MMF, 300 m over OM3 MMF |
| 40G-QSFP-LR4-SM1310 | 40GBASE-LR4, QSFP+ transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| 40G-QSFP-iLR4-SM1310 | 40GBASE-iLR4, QSFP+ transceiver, 1310 nm, Duplex LC, 2 km over SMF |
| 40G-QSFP-LX4-SM1310 | 40GBASE-LX4, QSFP+ transceiver, 1310 nm, Duplex LC, 150 m over OM3/OM4 MMF, 2 km over SMF |
| 40G-AOC-5M | 40GBASE, QSFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
100GE
| Model | Description |
| 100G-QSFP-SR-MM850 | 100GBASE-SR, QSFP28 transceiver, 850 nm, MPO 1 x 12, 100 m over OM4 MMF, 70 m over OM3 MMF |
| 100G-QSFP-LR4-SM1310 | 100GBASE-LR4, QSFP28 transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| 100G-AOC-10M | 100GBASE, QSFP28 active optical cable (AOC), 10 m, including one cable and two optical transceivers |
CWDM Transceiver
| Model | Description |
| SFG-LR-SM | 1GBASE-LR, core switch-side SFG CWDM transceiver, integration of 8 different wavelengths, BiDi LC, 10 km over SMF |
| SFM-LR-SM | 2.5GBASE-LR, core switch-side SFM CWDM transceiver, integration of 8 different wavelengths, BiDi LC, 10 km over SMF |
| SFX-LR-SM | 10GBASE-LR, core switch-side SFX CWDM transceiver, integration of 8 different wavelengths, BiDi LC, 10 km over SMF |