RG-S7810C-X 10 RU Modular Campus Core Switch

Highlight Features

  • Compact chassis design with a height of 10 RU, improving cabinet space utilization
  • Orthogonal Clos architecture, providing a backplane-free design and ensuring non-blocking packet forwarding and high-speed transmission without packet loss
  • VSU, delivering flexible networking capabilities and high performance
  • Hardware-level multi-protection, delivering carrier-grade reliability
  • Combination with the UNC, offering simplified and efficient O&M

Key Specification

 

Module slot  2 x supervisor module slots

8 x line card slots

4 x switch fabric module slots

4 x power module slots

2 x fan module slots 

Operating temperature  0°C to 50°C (32°F to 122°F) 
System packet forwarding rate  14300 Mpps  System switching capacity  19200 Gbps 
Unit dimensions (W x D x H)  442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.)  Unit weight  43.55 kg (96.01 lbs, empty chassis with 2 fan modules) 

 

Features

Modular Core Switch RG-S7810C-X

Compact chassis design with a height of 10 RU improves cabinet space utilization.

Eight line card slots support a wide range of cards that provide various port types, including high-density color optical cards, catering to the diverse needs of small, medium, and large-scale campus deployments.

VSU, Delivering Flexible Networking Capabilities and High Performance

VSU technology virtualizes multiple physical switches into one logical unit with a single IP address to realize unified management, simplifying O&M.

Fast link failover within 50 to 200 milliseconds ensures nonstop transmission of critical services.

Hardware-Level Multi-Protection, Delivering Carrier-Grade Reliability

1+1 Supervisor module Redundancy

1+1 hot standby ensures nonstop switch services.

Dual-Boot Redundancy

Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.

N+M Power Supply Redundancy

1+1 hot standby ensures nonstop switch services.

1+1 Fan Module Redundancy

Two axial flow fans for factory delivery support 256-level speed regulation and precise temperature control, reducing energy consumption and noise.

Ruijie Unified Networking Central (RG-UNC) Visualized Management, Automated and Effortless Operations

RG-UNC, a unified visual management platform, supports real-time monitoring of key devices and links, fine-grained alarms, centralized configuration backup and recovery, network-wide management, plug-and-play, and rapid deployment, enhancing O&M efficiency.

 

Specifications

Hardware Specifications (with -CM Series Supervisor Module)

Port specifications RG-S7805C RG-S7808C RG-S7810C
Module slot 2 x supervisor module slots

3 x line card slots

2 x power module slots

1 x fan module slot

2 x supervisor module slots

6 x line card slots

4 x power module slots

2 x fan module slots

2 x supervisor module slots

8 x line card slots (slot 7 does not support the EB line card)

2 x switch fabric module slots

4 x power module slots

2 x fan module slots

Supervisor module M7805C-CM II M7808C-CM II M7810C-CM

M7810C-CM-F

Switch fabric module / M7808C-CM II (switch fabric module integrated with supervisor module) M7810C-FE-D I (must be used with M7810C-CM)

M7810C-FE-F I (must be used with M7810C-CM-F)

M7810C-CM, M7810C-CM-F (switch fabric module integrated with supervisor module)

line card M7805C-CM II supports the following 9 modules:

● M7800C-32XS4QXS-DA

● M7800C-24GT24SFP4XS-EB

● M7800C-24SFP/12GT4XS-EB

● M7800C-48GT4XS-EB

● M7800C-48SFP4XS-EB

● M7800C-48GT-FA

● M7800C-48SFP-FA

● M7800C-48XS-FB

● M7800C-8CQ-FB

*1

M7808C-CM II supports the following 9 modules:

● M7800C-32XS4QXS-DA

● M7800C-24GT24SFP4XS-EB

● M7800C-24SFP/12GT4XS-EB

● M7800C-48GT4XS-EB

● M7800C-48SFP4XS-EB

● M7800C-48GT-FA

● M7800C-48SFP-FA

● M7800C-48XS-FB

● M7800C-8CQ-FB

*1

M7810C-CM supports the following 5 modules:

● M7800C-32XS4QXS-DA

● M7800C-24GT24SFP4XS-EB

● M7800C-24SFP/12GT4XS-EB

● M7800C-48GT4XS-EB

● M7800C-48SFP4XS-EB

M7810C-CM-F supports the following 4 modules:

● M7800C-48GT-FA

● M7800C-48SFP-FA

● M7800C-48XS-FB

● M7800C-8CQ-FB

*1

Power module RG-PA300I-F

RG-PA460I-F

RG-PA1000I-F

RG-PA600I-F

RG-PA1600I-F

RG-PA600I

RG-PA1600I

Fan module M05C-FAN (pre-installed 1) M08-FAN (pre-installed 2) M10C-FAN (pre-installed 2)
Module management port M7805C-CM II:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7808C-CM II:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-CM:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-CM-F:

● 1 x RJ45 console port *2 

● 1 x mini USB console port *2

● 1 x RJ45 MGMT port

USB M7805C-CM II: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) M7808C-CM II: 2 x USB 2.0 ports (no capacity limit, 2G/4G/8G/16G/32G capacity tested) M7810C-CM: 1 x USB 2.0 port

M7810C-CM-F: 1 x USB 2.0 port

(no capacity limit, 2G/4G/8G/16G/32G capacity tested)

*1 Note: FA/FB series cannot be used with EB series or DA series.

*2 Note: Only one console port is allowed to be used at the same time. The mini USB console port has a higher priority.

System specifications RG-S7805C RG-S7808C RG-S7810C
System packet forwarding rate *3 4500 Mpps 9000 Mpps 12000 Mpps
System switching capacity *4 6000 Gbps 12000 Gbps 16000 Gbps
CPU Supervisor module:

● M7805C-CM II: quad-core CPU, each core with the clock speed of 1.0 GHz

Line card

● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz

● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz

Supervisor module:

● M7808C-CM II: quad-core CPU, each core with the clock speed of 1.5 GHz

Line card

● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz

● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz

Supervisor module:

● M7810C-CM, M7810C-CM-F: quad-core CPU, each core with the clock speed of 1.5 GHz

Line card

● EB card: quad-core CPU, each core with the clock speed of 1.0 GHz

● DA/FA/FB card: quad-core CPU, each core with the clock speed of 1.5 GHz

Switch fabric module

● M7810C-FE-D I, M7810C-FE-F I: quad-core CPU, each core with the clock speed of 1.5 GHz

Real-time clock (RTC) M7805C-CM II: supported M7808C-CM II: supported M7810C-CM/M7810C-CM-F: supported
BootROM M7805C-CM II:8 MB

EB card: 8 MB

DA/FA/FB card: 16 MB

M7808C-CM II: 16 MB

EB card: 8 MB

DA/FA/FB card: 16 MB

M7810C-CM/M7810C-CM-F: 16 MB

EB card: 8 MB

DA/FA/FB card: 16 MB

M7810C-FE-D I/M7810C-FE-F I: 16 MB

Flash memory M7805C-CM II: 1 GB

EB card: 512 MB

DA/FA/FB card: 8 GB

M7808C-CM II: 8 GB

EB card: 512 MB

DA/FA/FB card: 8 GB

M7810C-CM/M7810C-CM-F: 8 GB

EB card: 512 MB

DA/FA/FB card: 8 GB

M7810C-FE-D I/M7810C-FE-F I: 8 GB

Memory M7805C-CM II: 4 GB DDR3

EB card: 1 GB DDR3

DA card: 1 GB DDR4

FA/FB card: 2 GB DDR4

M7808C-CM II: 4 GB DDR4

EB card: 1 GB DDR3

DA card: 1 GB DDR4

FA/FB card: 2 GB DDR4

M7810C-CM/M7810C-CM-F: 4 GB DDR4

EB card: 1 GB DDR3

DA card: 1 GB DDR4

FA/FB card: 2 GB DDR4

M7810C-FE-D I: 1 GB DDR4

M7810C-FE-F I: 2 GB DDR4

Switch buffer EB: 4 MB

FB: 32 MB

FA: 8 MB

DA: 16 MB

EB: 4 MB

FB: 32 MB

FA: 8 MB

DA: 16 MB

EB: 4 MB

FB: 32 MB

FA: 8 MB

DA: 16 MB

*3 means the system’s packet forwarding rate.

*4 means the system’s switching capacity.

Power supply and consumption RG-S7805C RG-S7808C RG-S7810C
Power supply 2 x pluggable power modules 4 x pluggable power modules 4 x pluggable power modules
Power input RG-PA300I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 5 A

RG-PA460I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz

● Maximum input current: 6 A

RG-PA1000I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA1600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 16 A

RG-PA600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 8 A

RG-PA1600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 16 A

Maximum output power RG-PA300I-F: 300 W

RG-PA460I-F: 460 W

RG-PA1000I-F:

● 100 V AC to 176 V AC: 800 W

● 176 V AC to 240 V AC: 1000 W

RG-PA600I-F: 600 W

RG-PA1600I-F:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

RG-PA600I: 600 W

RG-PA1600I:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

Module power consumption M05C-FAN: < 80 W

M7805C-CM II: < 21 W

M08-FAN: < 88 W

M7808C-CM II: < 50 W

M10C-FAN: < 216 W

M7810C-CM: < 50 W

M7810C-CM-F: < 110 W

M7800C-32XS4QXS-DA: < 210 W

M7800C-24GT24SFP4XS-EB: < 88 W

M7800C-24SFP/12GT4XS-EB: < 85 W

M7800C-48GT4XS-EB: < 70 W

M7800C-48SFP4XS-EB: < 101 W

M7800C-48GT-FA: < 75 W

M7800C-48SFP-FA: < 95 W

M7800C-48XS-FB: < 160 W

M7800C-8CQ-FB: < 130 W

 

Dimensions and Weight RG-S7805C RG-S7808C RG-S7810C
Unit dimensions (W x D x H) 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.) 442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.)
Shipping dimensions (W x D x H) 750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.) 710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.) 845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.)
Rack height 4 RU 10 RU 10 RU
Unit weight 12.42 kg (27.38 lbs, empty chassis with 1 fan module) 35.60 kg (78.48 lbs, empty chassis with 2 fan modules) 43.60 kg (96.01 lbs, empty chassis with 2 fan modules)
Shipping weight 28.05 kg (61.84 lbs) 43.93 kg (96.85 lbs) 68.30 kg (150.58 lbs)

 

Environment and reliability RG-S7805C RG-S7808C RG-S7810C
Temperature Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Humidity Operating humidity: 10% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH (non-condensing)

Altitude Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Mean time between failure (MTBF) 216,000 hours (about 24 years) 216,000 hours (about 24 years) 342,000 hours (about 39 years)
Fan 1 x pluggable fan module (pre-installed) 2 x pluggable fan modules (pre-installed) 2 x pluggable fan modules (pre-installed)
Heat dissipation Supervisor module: right-to-left airflow

Line card: right-to-rear airflow

Power module: built-in fan modules drawing air outward, front-to-rear airflow

Supervisor module: right-to-rear airflow

Line card: right-to-rear airflow

Power module: front-to-rear airflow

Supervisor module: front-to-rear airflow

Line card: side-to-rear airflow

FE card: front-to-rear airflow

Acoustic noise 27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

Supervisor module redundancy 1+1 redundancy 1+1 redundancy 1+1 redundancy (same model)
Power module redundancy 1+1 redundancy (same model) N+M redundancy (same model) N+M redundancy (same model)
Fan redundancy Not supported 1+1 redundancy 1+1 redundancy
Module hot swapping Supported Supported Supported
Power module hot swapping Supported Supported Supported
Fan module hot swapping Supported Supported Supported
Cable hot swapping All ports on line cards support hot swapping of cables.

The switch-mode power supply supports hot swapping of power cords.

Power supply monitoring Monitoring of the model, temperature, power, and voltage of the power supply module

Power supply failure alarming

Control of line card power-on based on the power supply status

Fan monitoring Fan speed adjustment: 256 levels

Fan failure alarming

Temperature monitoring Over-temperature alarming
ESD ESD contact/air discharge: 6 kV/8 kV

ESD susceptibility contact/air discharge: 8 kV/15 kV

Surge protection MGMT port: 4 kV

Service port: 4 kV

Power port: 6 kV

 

Certifications and regulatory compliance RG-S7805C RG-S7808C RG-S7810C
Safety regulation IEC 62368-1
EMC regulation EN 300386, EN 55032 Class A, EN 55035,

EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11

RoHS European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863

 

Hardware Specifications (with -X Series Supervisor Module)

Port specifications RG-S7805C RG-S7808C RG-S7810C-X
Module slot 2 x supervisor module slots

3 x line card slots

2 x power module slots

1 x fan module slot

2 x supervisor module slots

6 x line card slots

4 x power module slots

2 x fan module slots

2 x supervisor module slots

8 x line card slots

4 x switch fabric module slots

4 x power module slots

2 x fan module slots

Supervisor module M7805C-CM-X M7808C-CM-X M7810C-CM-X
Switch fabric module / M7808C-CM-X (switch fabric module integrated with supervisor module) M7810C-FE-X I

M7810C-FE-X II

line card M7800C-48GT4XS-XA

M7800C-48SFP4XS-XA

M7800C-24GT8SFP8XS-XA

M7800C-32XS-XA

M7800C-52XS-XB

M7800C-12CQ-XB

M7800C-48XT-P-XB

M7800C-48GT4XS-XA

M7800C-48SFP4XS-XA

M7800C-24GT8SFP8XS-XA

M7800C-32XS-XA

M7800C-52XS-XB

M7800C-12CQ-XB

M7800C-48XT-P-XB

M7800C-8SFG-XB

M7800C-8SFX-XB

M7800C-48GT4XS-XA

M7800C-48SFP4XS-XA

M7800C-24GT8SFP8XS-XA

M7800C-32XS-XA

M7800C-52XS-XB

M7800C-12CQ-XB

M7800C-48XT-P-XB

M7800C-8SFG-XB

M7800C-8SFX-XB

Power module RG-PA300I-F

RG-PA460I-F

RG-PA1000I-F

RG-PA600I-F

RG-PA1600I-F

RG-PA600I

RG-PA1600I

RG-PD600I

Fan module M05C-FAN (pre-installed 1) M08-FAN (pre-installed 2) M10C-FAN (pre-installed 2)
Module management port M7805C-CM-X:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7808C-CM-X:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-CM-X:

● 1 x RJ45 console port

● 1 x RJ45 MGMT port

M7810C-FE-X I/II:

● 1 x RJ45 console port

USB M7805C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) M7808C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested) M7810C-CM-X: 1 x USB 2.0 port (no capacity limit, 2G/4G/8G/16G/32G capacity tested)

 

System specifications RG-S7805C RG-S7808C RG-S7810C-X
System packet forwarding rate *3 4500 Mpps 9000 Mpps 14300 Mpps
System switching capacity *4 6000 Gbps 12000 Gbps 19200 Gbps
CPU Supervisor module:

● M7805C-CM-X: quad-core processor, each core 2.2 GHz

Line card:

● XA/XB series line card: quad-core processor, each core 2.2 GHz

Supervisor module:

● M7808C-CM-X: quad-core processor, each core 2.2 GHz

Line card:

● XA/XB series line card: quad-core processor, each core 2.2 GHz

Supervisor module:

● M7810C-CM-X: quad-core processor, each core 2.2 GHz

Line card:

● XA/XB series line card: quad-core processor, each core 2.2 GHz

Real-time clock (RTC) M7805C-CM-X: supported M7808C-CM-X: supported M7810C-CM-X: supported
BootROM M7805C-CM-X: 16 MB

XA/XB card: 16 MB

M7808C-CM-X: 16 MB

XA/XB card: 16 MB

M7810C-CM-X: 16 MB

M7810C-FE-X I/II: 16 MB

XA/XB card: 16 MB

Flash memory M7805C-CM-X: 8 GB

XA/XB card: 8 GB

M7808C-CM-X: 8 GB

XA/XB card: 8 GB

M7810C-CM-X: 8 GB

M7810C-FE-X I/II: 8 GB

XA/XB card: 8 GB

Memory M7805C-CM-X: 4 GB DDR4

XA/XB card: 4 GB DDR4

M7808C-CM-X: 4 GB DDR4

XA/XB card: 4 GB DDR4

M7810C-CM-X: 4 GB DDR4

M7810C-FE-X I: 1 GB DDR4

M7810C-FE-X II: 4 GB DDR4

XA/XB card: 4 GB DDR4

Switch buffer XA series line card (excluding M7800C-32XS-XA): 4 MB

XB series line card: 35 MB

M7800C-32XS-XA: 35 MB

XA series line card (excluding M7800C-32XS-XA): 4 MB

XB series line card: 35 MB

M7800C-32XS-XA: 35 MB

XA series line card (excluding M7800C-32XS-XA): 4 MB

XB series line card: 35 MB

M7800C-32XS-XA: 35 MB

*3 means the system’s packet forwarding rate.

*4 means the system’s switching capacity.

 

Power supply and consumption RG-S7805C RG-S7808C RG-S7810C-X
Power supply 2 x pluggable power modules 4 x pluggable power modules 4 x pluggable power modules
Power input RG-PA300I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 5 A

RG-PA460I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 290 V AC; 45 Hz to 63 Hz

● Maximum input current: 6 A

RG-PA1000I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 10 A

RG-PA1600I-F (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 16 A

RG-PA600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

● Maximum input current: 8 A

RG-PA1600I (AC input):

● Rated input voltage: 100 V AC to 240 V AC; 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 16 A

RG-PD600I (DC input):

● Rated input voltage: –48 V DC

● Maximum input voltage: –40 V DC to –75 V DC

● Maximum input current: 20 A

Maximum output power RG-PA300I-F: 300 W

RG-PA460I-F: 460 W

RG-PA1000I-F:

● 100 V AC to 176 V AC: 800 W

● 176 V AC to 240 V AC: 1000 W

RG-PA600I-F: 600 W

RG-PA1600I-F:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

RG-PA600I: 600 W

RG-PA1600I:

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

RG-PD600I: 600 W

Module power consumption M05C-FAN: < 80 W

M7805C-CM-X: < 40 W

M08-FAN: < 88 W

M7808C-CM-X: < 62 W

 

 

M7800C-8SFG-XB: < 250 W

M7800C-8SFX-XB: < 250 W

M10C-FAN: < 216 W

M7810C-CM-X: < 60 W

M7810C-FE-X I: < 50 W

M7810C-FE-X II: < 160 W

M7800C-8SFG-XB: < 250 W

M7800C-8SFX-XB: < 250 W

M7800C-48GT4XS-XA: < 85 W

M7800C-48SFP4XS-XA: < 117 W

M7800C-24GT8SFP8XS-XA: < 95 W

M7800C-32XS-XA: < 149 W

M7800C-52XS-XB: < 250 W

M7800C-12CQ-XB: < 240 W

M7800C-48XT-P-XB: < 300 W


If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB.

Hardware Specifications M78-PSE-X
Fixed service port 2 x PoE out ports
Module slot 2 x power module slots
Power module RG-PA1600I-PL
Power supply 2 x pluggable power modules
Power input RG-PA1600I-PL (AC input):

● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz

● Maximum input voltage: 90 V AC to 264 V AC; 47 Hz to 63 Hz

● Maximum input current: 16 A

Maximum output power RG-PA1600I-PL

● 100 V AC to 176 V AC: 1200 W

● 176 V AC to 240 V AC: 1600 W

PoE output power Each PoE out port provides up to 1,440 W of power
Unit dimensions (W x D x H) 400.0 mm x 420.0 mm x 44.7 mm (15.75 in. x 16.54 in. x 1.76 in.)
Unit weight 5.0 kg (11.02 lbs)
Temperature Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
Humidity Operating humidity: 10% to 90% RH (non-condensing)
Storage humidity: 5% to 95% RH (non-condensing)
Mean time between failure (MTBF) 4,289,000 hours (about 489 years)
Power module redundancy 1+1 redundancy (same model)

 

Dimensions and Weight RG-S7805C RG-S7808C RG-S7810C-X
Unit dimensions (W x D x H) 442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in.) 442.0 mm x 465.0 mm x 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) 442.5 mm x 560.0 mm x 442.0 mm (17.42 in. x 22.05 in. x 17.40 in.)
Shipping dimensions (W x D x H) 750.0 mm x 600.0 mm x 455.0 mm (29.53 in. x 23.62 in. x 17.91 in.) 710.0 mm x 590.0 mm x 735.0 mm (27.95 in. x 23.23 in. x 28.94 in.) 845.0 mm x 685.0 mm x 770.0 mm (33.27 in. x 26.97 in. x 30.31 in.)
Rack height 4 RU 10 RU 10 RU
Unit weight 12.42 kg (27.38 lbs, empty chassis with 1 fan module) 35.6 kg (78.48 lbs, empty chassis with 2 fan modules) 43.55 kg (96.01 lbs, empty chassis with 2 fan modules)
Shipping weight 28.05 kg (61.84 lbs) 43.93 kg (96.85 lbs) 68.30 kg (150.58 lbs)

 

Environment and reliability RG-S7805C RG-S7808C RG-S7810C-X
Temperature Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Humidity Operating humidity: 10% to 90% RH (non-condensing)

Storage humidity: 5% to 95% RH (non-condensing)

Altitude Operating altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Storage altitude: –500 m to +5,000 m (–1,640.42 ft. to +16,404.20 ft.)

Mean time between failure (MTBF) 216,000 hours (about 24 years) 216,000 hours (about 24 years) 342,000 hours (about 39 years)
Fan 1 x pluggable fan module (pre-installed) 2 x pluggable fan modules (pre-installed) 2 x pluggable fan modules (pre-installed)
Heat dissipation Supervisor module: right-to-left airflow

Line card: right-to-rear airflow

Power module: built-in fan modules drawing air outward, front-to-rear airflow

Supervisor module: right-to-rear airflow

Line card: right-to-rear airflow

Power module: front-to-rear airflow

Supervisor module: front-to-rear airflow

Line card: side-to-rear airflow

FE card: front-to-rear airflow

Acoustic noise 27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

27°C (80.6°F): 70 dB

Max Noise: 77 dB

Supervisor module redundancy 1+1 redundancy 1+1 redundancy 1+1 redundancy
Power module redundancy 1+1 redundancy (same model) N+M redundancy (same model) N+M redundancy (same model)
Fan redundancy Not supported 1+1 redundancy 1+1 redundancy
Module hot swapping Supported Supported Supported
Power module hot swapping Supported Supported Supported
Fan module hot swapping Supported Supported Supported
Cable hot swapping All ports on line cards support hot swapping of cables.

The switch-mode power supply supports hot swapping of power cords.

Power supply monitoring Monitoring of the model, temperature, power, and voltage of the power supply module

Power supply failure alarming

Control of line card power-on based on the power status

Fan monitoring Fan speed adjustment: 256 levels

Fan failure alarming

Temperature monitoring Over-temperature warning
ESD ESD contact/air discharge: 6 kV/8 kV

ESD susceptibility contact/air discharge: 8 kV/15 kV

Surge protection MGMT port: 4 kV

Service port: 4 kV

Power port: 6 kV

 

Certifications and regulatory compliance RG-S7805C RG-S7808C RG-S7810C-X
Safety regulation IEC 62368-1
EMC regulation EN 300386, EN 55032 Class A, EN 55035,

EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3,

EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11

RoHS European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863

 

Software Specifications (with -CM Series Supervisor Module)

Feature RG-S7800C Series
Ethernet switching Jumbo frame (maximum length: 9,216 bytes)
802.3az EEE
Maximum number of VLANs that can be created: 4,094
Voice VLAN
Super-VLAN and private VLAN
MAC address-based, port-based, protocol-based, and IP subnet-based VLAN assignment
GVRP
Basic QinQ and selective QinQ
STP (IEEE 802.1.d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
ERPS (G.8032)
LLDP/LLDP-MED
IP service Static and dynamic ARP
DHCP client
DHCP relay
DHCP server
DHCP snooping
DNS
DHCPv6 client, DHCPv6 relay, and DHCPv6 snooping
Neighbor Discovery (ND) and ND snooping
Manual tunnel, automatic tunnel, and ISATAP tunnel for IPv6
GRE tunnel
IP routing Static routing
RIP and RIPng
OSPFv2 and OSPFv3
GR
IPv4/IPv6 IS-IS
BGP4 and BGP4+
EVPN
IPv4/IPv6 VRF
Policy-based routing (PBR)
IPv4 and IPv6 ECMP
Multicast IGMP v1/v2/v3
IGMP snooping v1/v2/v3
IGMP proxy
IGMP fast leave
PIM-DM, PIM-SM, and PIM-SSM
PIM-SSM for IPv4 and IPv6
MSDP to achieve inter-domain multicast
MLDv1 and MLDv2
Multicast static routing
MLD v1/v2 snooping
PIM-SMv6
Multicast source IP address check

Multicast source port check

MPLS MPLS IPv6
MPLS L3VPN
MPLS 6VPE
MPLS MIB (RFC 1273, RFC 4265, and RFC 4382)
ACL and QoS Standard IP ACLs (hardware ACLs based on IP addresses)
Extended IP ACLs (hardware ACLs based on IP addresses or TCP/UDP port numbers)
Extended MAC ACLs (hardware ACLs based on source MAC addresses, destination MAC addresses, and optional Ethernet type)
Expert-level ACLs (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)
ACL80 and IPv6 ACL
Applying ACLs globally (hardware ACLs based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port number, protocol type, and time range)
ACL redirection
Port traffic identification
Port-based rate limiting
802.1p
Traffic classification based on 802.1p priorities, DSCP priorities, and IP precedences
CAR
Congestion management: SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ
Congestion avoidance: tail drop, RED, and WRED
Eight queues on each port
Security AAA
RADIUS authorization and accounting
TACACS+
Portal authentication, RADIUS, and TACACS+ login authentication
IEEE802.1X authentication, MAC address bypass (MAB) authentication, and interface-based and MAC address-based 802.1X authentication
Web authentication
Hypertext Transfer Protocol Secure (HTTPS)
SSHv1 and SSHv2
Global IP-MAC binding
ICMP
Port security
IP source guard
DAI
SAVI
ARP spoofing prevention
CPU Protect Policy (CPP) and NFPP
Various attack defense functions, including NFPP and ARP anti-attack
uRPF

Login authentication and password security

Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed.

Reliability Rapid Ethernet Uplink Protection (REUP)
Rapid Link Detection Protocol (RLDP), Layer 2 link connectivity detection, unidirectional link detection, and VLAN-based loop control
Data Link Detection Protocol (DLDP)
IPv4 VRRP v2/v3 and IPv6 VRRP
VRRP for the super-VLAN
BFD
RG-S7805C, RG-S7808C , RG-S7810C: 1+1 redundancy for supervisor modules
RG-S7805C: 1+1 redundancy for power supply

RG-S7808C , RG-S7810C: N+M redundancy for power supply

RG-S7805C: fan redundancy is not supported

RG-S7808C , RG-S7810C: 1+1 fan redundancy

Hot swapping of components
Hot patch and online installation of patches
GR for OSPF/IS-IS/BGP
BFD for VRRP/OSPF/BGP4/ISIS/ISISv6/static routing
Device virtualization VSU
NMS and maintenance SPAN, RSPAN, and ERSPAN
sFlow
NTP 
SNTP
FTP, TFTP, and Xmodem
SNMP v1/v2c/v3
RMON (1, 2, 3, 9)
NETCONF
CWMP
gRPC
OpenFlow Special 1.3

Flow table analysis defined by all protocols

Transmission of specified packets to the controller

Configuring the controller’s IP address and port

Notifying port status changes to the controller

Web-based NMS
Console/Telnet/SSH2.0 CLI configuration

Fault alarms and auto-recovery

System operation logging

VXLAN Layer 2 and Layer 3 VXLAN gateways

 

Software Specifications (with -X Series Supervisor Module)

Software Specifications RG-S7800C-X Series
Ethernet switching  Jumbo frame (maximum length: 9,216 bytes)
802.3az EEE
Maximum number of VLANs that can be created: 4,094
Voice VLAN
GVRP
IP subnet-based VLAN
MAC VLAN
Port-based VLAN
Private VLAN
protocol-based VLAN
Super-VLAN
Basic QinQ and selective QinQ
STP (IEEE 802.1.d)
RSTP (IEEE 802.1w)
MSTP (IEEE 802.1s)
ERPS (G.8032)
LLDP/LLDP-MED
Device Virtualization VSU
SDN OpenFlow 1.3

NETCONF

IP service Static and dynamic ARP
DHCP client
DHCP relay
DHCP server
DHCP snooping
DNS
DHCPv6 client
DHCPv6 relay
DHCPv6 snooping
Neighbor Discovery (ND) and ND snooping
FTP Server
FTP Client
NTP server
NTP Client
SNTP Client
TFTP Client
TFTP Server
IP routing Static routing
BGP4
BGP4+
IS-ISv4
IS-ISv6
OSPFv2
OSPFv3
RIP
RIPng
GR
Routing Policy
ECMP
IPv4/IPv6 VRF
Policy-based routing (PBR)
Multicast IGMP v1/v2/v3
IGMP snooping v1/v2
IGMP proxy
IGMP fast leave
PIM-DM
PIM-SM
PIM-SSM for IPv4 and IPv6
MSDP to achieve inter-domain multicast
MLDv1 and MLDv2
Multicast static routing
MLD v1/v2 snooping
PIM-SMv6
Multicast source IP address check
Multicast source port check
MPLS MPLS L3VPN
MPLS 6VPE
MPLS IPv6
MPLS forwarding
LDP
LSP
VXLAN VXLAN Layer 2 bridge
VXLAN Layer 3 gateway
EVPN VXLAN
ACL and QoS

 

Standard IP ACL
extended IP ACL
extended MAC ACL
Layer 2 and Layer 3 port ACL
VLAN ACL
Expert-level ACL
ACL 80
IPv6 ACL
Applying ACLs globally
ACL COUNTER
ACL LOGGING
ACL REMARK
802.1P
SP
WRR
SP+WFR
other queue scheduling mechanisms
RED/WRED
Rate limiting based on the inbound or outbound interface
MPLS QOS
Reliability RG-S7805C, RG-S7808C , RG-S7810C-X: 1+1 redundancy for supervisor modules
RG-S7805C: 1+1 redundancy for power supply

RG-S7808C , RG-S7810C-X: N+M redundancy for power supply

RG-S7805C: fan redundancy is not supported

RG-S7808C , RG-S7810C-X: 1+1 fan redundancy

Hot swapping of all components
Hot patching function for online patch upgrade
GR
BFD
VRRP
VRRP+
Faulty optical port isolation
Dual physical chips for boot systems
Security NFPP
CPP
DAI
port security
IP source guard
802.1X authentication
MAC address-based authentication
Portal authentication
RADIUS
TACACS+ login authentication
uRPF
SSHv2
IPv6 SAVI
Login authentication and password security
providing encrypted security channels for user login
Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed.
NMS and maintenance Console/AUX Modem/Telnet/SSH2.0 CLI configuration
File upload and download management using FTP, TFTP, and Xmodem
SNMP V1/V2c/V3
RMON
CWMP
GRPC
Fault alarm and auto-recovery
System operation logging
sFlow
SPAN
RSPAN
ERSPAN
VLAN mirroring
Web-based NMS
Energy-Saving Design IEEE 802.3az Energy Efficient Ethernet

 

 

Order Information

Switch Chassis

Model Description
RG-S7805C RG-S7805C switch, which can accommodate three line cards and two supervisor modules (supporting -CM series and -X series supervisor modules)
RG-S7808C RG-S7808C switch, which can accommodate six line cards and two supervisor modules (supporting -CM series and -X series supervisor modules)
RG-S7810C RG-S7810C switch, which can accommodate eight service cards, two supervisor modules, and two switch fabric modules (supporting -CM series supervisor modules)
RG-S7810C-X RG-S7810C-X switch, which can accommodate eight line cards, two supervisor modules, and four switch fabric modules (supporting -X series supervisor modules)

 

Supervisor Modules

Model Description
M7805C-CM II S7805C high-performance 2nd-generation supervisor module
M7808C-CM II S7808C high-performance 2nd-generation supervisor module
M7810C-CM S7810C high-performance 1st-generation supervisor module
M7810C-CM-F S7810C high-performance 2nd-generation supervisor module
M7805C-CM-X RG-S7805C high-performance supervisor module
M7808C-CM-X RG-S7808C high-performance supervisor module
M7810C-CM-X RG-S7810C-X high-performance supervisor module

Notes:

  • Different models cannot be interchanged.
  • Mandatory item, 1+1 redundancy supported, and at least one supervisor module must be configured.

 

Switch Fabric Modules

Model Description
M7810C-FE-D I RG-S7810C switch fabric module I
M7810C-FE-F I RG-S7810C 2nd-generation switch fabric module
M7810C-FE-X I RG-S7810C-X 1st-generation switch fabric module
M7810C-FE-X II RG-S7810C-X 2nd-generation switch fabric module

 

Line Cards

Working with -CM series supervisor module

Model Description
M7800C-32XS4QXS-DA 32 x 1GE/10GE SFP+ ports (LC) and 4 x 40GE QSFP+ ports (MPO), supporting splitting a 40GE port into 4 x 10GE optical ports
M7800C-24GT24SFP4XS-EB 24 x 10/100/1000BASE-T ports (RJ45), 24 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC)
M7800C-24SFP/12GT4XS-EB 24 x 100M/1GE SFP ports (LC), 12 x 10/100/1000BASE-T combo ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC)
M7800C-48GT4XS-EB 48 x 10/100/1000BASE-T ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC)
M7800C-48SFP4XS-EB 48 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC)
M7800C-48GT-FA 48 x 10/100/1000BASE-T ports (RJ45)
M7800C-48SFP-FA 48 x 100M/1GE SFP ports (LC)
M7800C-48XS-FB 48 x 1GE/10GE SFP+ ports (LC)
M7800C-8CQ-FB 8 x 40GE/100GE QSFP28 ports (LC)

Notes:

  • EB series line cards only interchanged with DA series line cards.
  • DA series line cards only interchanged with EB series line cards.
  • FA/FB series line cards cannot be interchanged with EB/DA series line cards.

 

Working with -X series supervisor module

Model Description
M7800C-48GT4XS-XA 48 x 10/100/1000BASE-T ports (RJ45) and 4 x 1GE/10GE SFP+ ports (LC)
M7800C-48SFP4XS-XA 48 x 100M/1GE SFP ports (LC) and 4 x 1GE/10GE SFP+ ports (LC)
M7800C-24GT8SFP8XS-XA 24 x 10/100/1000BASE-T ports (RJ45), 8 x 100M/1GE SFP ports (LC) and 8 x 1GE/10GE SFP+ ports (LC)
M7800C-32XS-XA 32 x 1GE/10GE SFP+ ports (LC)
M7800C-52XS-XB 52 x 1GE/10GE SFP+ ports (LC)
M7800C-12CQ-XB 12 x 40GE/100GE QSFP28 ports (MPO/LC). One 100GE port can be split into four 25GE ports and one 40GE port can be split into four 10GE ports.
M7800C-48XT-P-XB 48 x 100/1000/2.5G/5G/10GBASE-T ports (RJ45), supporting PoE/PoE+. Each PoE port provides up to 30 W of power. The maximum power is 1440 W over 48 ports (30 W x 48).

1 x PoE in port receives PoE/PoE+ power supply. If the PoE function is used, you need to separately configure the PoE power chassis M78-PSE-X and the power module RG-PA1600I-PL for M7800C-48XT-P-XB.

M7800C-8SFG-XB 8 x SFG ports (64 x 1GE logical channels). CWDM line card for RG-S7810C-X and RG-S7808C (used with the M7808C-CM-X supervisor module)
M7800C-8SFX-XB 8 x SFX ports (64 x 10GE logical channels) with each port backward compatible with the Gigabit rate. CWDM line card for RG-S7810C-X and RG-S7808C (used with the M7808C-CM-X supervisor module)

 

Power Chassis and Modules

Model Description
RG-PA300I-F 300 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C
RG-PA460I-F 460 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C
RG-PA600I 600 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7810C & RG-S7810C-X
RG-PA600I-F 600 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7808C
RG-PA1000I-F 1000 W AC power module, supporting redundancy, 10 A power cord, used with RG-S7805C
RG-PA1600I 1600 W AC power module, supporting redundancy, 16 A power cord, used with RG-S7810C & RG-S7810C-X
RG-PA1600I-F 1600 W AC power module, supporting redundancy, 16 A power cord, used with RG-S7808C
M78-PSE-X PoE power chassis. 2 x PoE out ports can power two PoE line cards through specialized PoE cables. 2 x power module slots, used together with RG-PA1600I-PL (working with -X series supervisor module)
RG-PA1600I-PL 1600 W PoE AC power module, supporting redundancy, 16 A power cord, used with M78-PSE-X (working with -X series supervisor module)
RG-PD600I 600 W DC power module, supporting redundancy, 20 A power cord, used with RG-S7810C-X

 

Optical Transceivers and Cables

1GE

Model Description
Mini-GBIC-GT 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a

The port needs to be configured with auto-negotiation

MINI-GBIC-SX-MM850 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF
MINI-GBIC-LX-SM1310 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF
MINI-GBIC-LH40-SM1310 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF
MINI-GBIC-ZX80-SM1550 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF
GE-SFP-LX20-SM1310-BIDI 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF
GE-SFP-LX20-SM1550-BIDI 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF
GE-SFP-LH40-SM1310-BIDI 1000BASE-LH, SFP transceiver, TX1310/RX1550, BiDi LC, 40 km over SMF
GE-SFP-LH40-SM1550-BIDI 1000BASE-LH, SFP transceiver, TX1550/RX1310, BiDi LC, 40 km over SMF
GE-SFP-LX03-SM1310-BIDI-I 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF
GE-SFP-LX03-SM1550-BIDI-I 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF

Note: BiDi transceivers must be used in pairs. If one end uses GE-SFP-LX20-SM1310-BIDI, the other end must use GE-SFP-LX20-SM1550-BIDI.

 

10GE

Model Description
XG-SFP-SR-MM850 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF
XG-SFP-LR-SM1310 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF
XG-SFP-ER-SM1550 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF
XG-SFP-ZR-SM1550 10GBASE-ZR, SFP+ transceiver, 1550nm, Duplex LC, 80 km over SMF
XG-SFP-LR10-SM1270-BIDI-I 10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF
XG-SFP-LR10-SM1330-BIDI-I 10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF
XG-SFP-AOC1M 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers
XG-SFP-AOC3M 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers
XG-SFP-AOC5M 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers

Note: BiDi transceivers must be used in pairs. If one end uses XG-SFP-LR10-SM1270-BIDI-I, the other end must use XG-SFP-LR10-SM1330-BIDI-I.

 

40GE

Model Description
40G-QSFP-LSR-MM850 40GBASE-LSR, QSFP+ transceiver, 850 nm, MPO 1 x 12, 400 m over OM4 MMF, 300 m over OM3 MMF
40G-QSFP-LR4-SM1310 40GBASE-LR4, QSFP+ transceiver, 1310 nm, Duplex LC, 10 km over SMF
40G-QSFP-iLR4-SM1310 40GBASE-iLR4, QSFP+ transceiver, 1310 nm, Duplex LC, 2 km over SMF
40G-QSFP-LX4-SM1310 40GBASE-LX4, QSFP+ transceiver, 1310 nm, Duplex LC, 150 m over OM3/OM4 MMF, 2 km over SMF
40G-AOC-5M 40GBASE, QSFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers

 

100GE

Model Description
100G-QSFP-SR-MM850 100GBASE-SR, QSFP28 transceiver, 850 nm, MPO 1 x 12, 100 m over OM4 MMF, 70 m over OM3 MMF
100G-QSFP-LR4-SM1310 100GBASE-LR4, QSFP28 transceiver, 1310 nm, Duplex LC, 10 km over SMF
100G-AOC-10M 100GBASE, QSFP28 active optical cable (AOC), 10 m, including one cable and two optical transceivers

 

CWDM Transceiver

Model Description
SFG-LR-SM 1GBASE-LR, core switch-side SFG CWDM transceiver, integration of 8 different wavelengths, BiDi LC, 10 km over SMF
SFM-LR-SM 2.5GBASE-LR, core switch-side SFM CWDM transceiver, integration of 8 different wavelengths, BiDi LC, 10 km over SMF
SFX-LR-SM 10GBASE-LR, core switch-side SFX CWDM transceiver, integration of 8 different wavelengths, BiDi LC, 10 km over SMF

 

Models

RG-S7810C-X

Series

RG-S7800C & RG-S7800C-X Series Switches