RG-S6580-24DC8QC – Next-Generation Data Center 200GE Fixed Access Switch, 400GE Uplink (Backward Compatible with 100GE)

Highlight Features

  • Various ports – 24 x 200GE QSPF56 ports and 8 x 400GE QSPF-DD ports, allowing flexible networking
  • Hardware-level redundancy, ensuring service continuity
  • Communication at the maximum distance of 120 km and easy DCI
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry-based network monitoring and automated O&M, making management simple and efficient

Key Specification

 

Switching capacity  16.0 Tbps  Packet forwarding rate  5350 Mpps 
Service port  24 x 40G/100G/200G QSFP56 ports

8 x 100G/400G QSFP-DD ports 

Dimensions (W x D x H)  442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) 
Operating temperature  0°C to 40°C (32°F to 104°F)  Operating humidity  10% RH to 90% RH (non-condensing) 

 

Features

Data Center 200GE Access Switch RG-S6580-24DC8QC

Data center 200GE access switch with 1 RU, various ports, improved data forwarding capability,

and flexible scenario deployment 200GE/100GE server access and evolution to 100GE/400GE data center networks

Hardware-level Redundancy, Ensuring Service Continuity

Hot-Swappable Redundant Power Modules

Power modules in 1+1 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links

Hot-Swappable Redundant Fan Modules

Fan modules in 5+1 redundancy mode, intelligent fan speed adjustment, and highly-efficient heat dissipation, building low-carbon data centers

Communication at the Maximum Distance of 120 km and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale data center network to adapt to growing high-bandwidth services

Lossless Ethernet with RDMA E2E Communication and Zero Packet Loss

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU

burden and effectively solves the network latency problem.

PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy. 

The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

 

Specifications

Hardware Specifications

Item RG-S6580-48CQ8QC RG-S6580-24DC8QC
Dimensions (W x D x H) 442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) 442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.)
Rack height 1 RU 1 RU
Unit weight 11.5 kg (25.35 lbs., a chassis with two power modules and six fan modules) 11 kg (24.25 lbs., a chassis with two power modules and six fan modules)
Switching capacity 16.0 Tbps 16.0 Tbps
Packet forwarding rate 5350 Mpps 5350 Mpps
Service port 48 x 100G DSFP ports

8 x 100G/400G QSFP-DD ports

24 x 100G/200G QSFP56 ports

8 x 100G/400G QSFP-DD ports

Management port 1 x RJ45 console port

1 x RJ45 MGMT port

1 x RJ45 console port

1 x RJ45 MGMT port

USB port 1 x USB 2.0 port (Type A connector) 1 x USB 2.0 port (Type A connector)
Module slot 2 x power module slots

6 x fan module slots

2 x power module slots

6 x fan module slots

Power consumption Maximum power consumption: 742 W

Typical power consumption: 633 W

Static power consumption: 178 W

Maximum power consumption: 850 W

Typical power consumption: 700 W

Static power consumption: 300 W

Power input RG-PA1200I-F (AC input)

Rated input voltage:

100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz

Maximum input voltage:

90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current:

13.8 A(100 V AC to 127 V AC)

8.5 A (200 V AC to 240 V AC)

Power port type: C14

 

RG-PA1200I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 300 V DC

Rated current: 6.5 A

Power port type: C14

RG-PA1200I-F (AC input)

Rated input voltage:

100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz

Maximum input voltage:

90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current:

13.8 A(100 V AC to 127 V AC)

8.5 A (200 V AC to 240 V AC)

Power port type: C14

 

RG-PA1200I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 300 V DC

Rated current: 6.5 A

Power port type: C14

Temperature Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Operating temperature: 0°C to 40°C (32°F to 104°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Humidity Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Altitude Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Cooling Air cooling, front-to-rear airflow (port-side intake) Air cooling, front-to-rear airflow (port-side intake)


Software Specifications

Item RG-S6580-48CQ8QC RG-S6580-24DC8QC
Layer 2 Protocols IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB)
Layer 3 Protocols (IPv4) BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP
IPv6 Basic Protocols Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS
IPv6 Features Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+
Data Center Features PFC, ECN, and other data center features

RDMA

VXLAN bridge

VXLAN gateway

IPv6 VXLAN over IPv4

IPv4 VXLAN over IPv4

ECN over VXLAN

PFC over VXLAN

Visualization gRPC

sFlow sampling

IPFIX

QoS Mapping of IEEE 802.1p, DSCP, and ToS priorities
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding
HA Design GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules
Security Features Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management
Management Mode SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm
Other Protocols DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog

 

Order Information

Chassis, Fan Module

Product Model Description
RG-S6580-48CQ8QC 48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports

Two power slots and six fan slots

The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules.

RG-S6580-24DC8QC 24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports

Two power slots and six fan slots

The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules.

 

Power Supply Module

Product Model Description
RG-PA1200I-F 1200 W AC module (AC/240 V HVDC)

 

Fan Module

Product Model Description
M1HFAN II-F Fan module (front-to-rear ventilation)

 

100GE Optical Transceivers

Model Description
100G-AOC-5M 100G AOC, QSFP28 form factor, 5 m (16.40 ft.)
100G-AOC-10M 100G AOC, QSFP28 form factor, 10 m (32.81 ft.)
100G-QSFP-SR-MM850 100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over multimode fiber (MMF)
100G-QSFP-iLR4-SM1310 100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
100G-QSFP-LR4-SM1310 100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF
100G-QSFP-ER4-SM1310 100GE ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF

 

400GE Optical Transceivers

Model Description
400G-QDD-SR8-MM850 400G optical transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF
400G-QDD-DR4-SM1310 400G optical transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF
400G-QDD-FR4-SM1310 400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
*400G-QDD-ZR-SM1550 400G ZR optical transceiver, QSFP-DD, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF

 

Models

RG-S6580-24DC8QC

Series

RG-S6580 Series