Key Specification
| Switching capacity | 16.0 Tbps | Packet forwarding rate | 5350 Mpps |
| Service port | 24 x 40G/100G/200G QSFP56 ports
8 x 100G/400G QSFP-DD ports |
Dimensions (W x D x H) | 442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) |
| Operating temperature | 0°C to 40°C (32°F to 104°F) | Operating humidity | 10% RH to 90% RH (non-condensing) |
Features
Data Center 200GE Access Switch RG-S6580-24DC8QC
Data center 200GE access switch with 1 RU, various ports, improved data forwarding capability,
and flexible scenario deployment 200GE/100GE server access and evolution to 100GE/400GE data center networks
Hardware-level Redundancy, Ensuring Service Continuity
Hot-Swappable Redundant Power Modules
Power modules in 1+1 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links
Hot-Swappable Redundant Fan Modules
Fan modules in 5+1 redundancy mode, intelligent fan speed adjustment, and highly-efficient heat dissipation, building low-carbon data centers
Communication at the Maximum Distance of 120 km and Easy DCI
400GE ZR/ZR+ optical modules are used for interconnection, reducing Optical Transport Units (OTUs) and helping a cloud or hyper-scale data center network to adapt to growing high-bandwidth services
Lossless Ethernet with RDMA E2E Communication and Zero Packet Loss
With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU
burden and effectively solves the network latency problem.
PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission
Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient
The switch enabled with telemetry provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.
Specifications
Hardware Specifications
| Item | RG-S6580-48CQ8QC | RG-S6580-24DC8QC |
| Dimensions (W x D x H) | 442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) | 442 mm x 670 mm x 43.6 mm (17.40 in. x 26.38 in. x 1.72 in.) |
| Rack height | 1 RU | 1 RU |
| Unit weight | 11.5 kg (25.35 lbs., a chassis with two power modules and six fan modules) | 11 kg (24.25 lbs., a chassis with two power modules and six fan modules) |
| Switching capacity | 16.0 Tbps | 16.0 Tbps |
| Packet forwarding rate | 5350 Mpps | 5350 Mpps |
| Service port | 48 x 100G DSFP ports
8 x 100G/400G QSFP-DD ports |
24 x 100G/200G QSFP56 ports
8 x 100G/400G QSFP-DD ports |
| Management port | 1 x RJ45 console port
1 x RJ45 MGMT port |
1 x RJ45 console port
1 x RJ45 MGMT port |
| USB port | 1 x USB 2.0 port (Type A connector) | 1 x USB 2.0 port (Type A connector) |
| Module slot | 2 x power module slots
6 x fan module slots |
2 x power module slots
6 x fan module slots |
| Power consumption | Maximum power consumption: 742 W
Typical power consumption: 633 W Static power consumption: 178 W |
Maximum power consumption: 850 W
Typical power consumption: 700 W Static power consumption: 300 W |
| Power input | RG-PA1200I-F (AC input)
Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 13.8 A(100 V AC to 127 V AC) 8.5 A (200 V AC to 240 V AC) Power port type: C14
RG-PA1200I-F (HVDC input): Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated current: 6.5 A Power port type: C14 |
RG-PA1200I-F (AC input)
Rated input voltage: 100 V AC to 127 V AC, 200 V AC to 240 V AC, 50 Hz/60Hz Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 13.8 A(100 V AC to 127 V AC) 8.5 A (200 V AC to 240 V AC) Power port type: C14
RG-PA1200I-F (HVDC input): Rated input voltage: 240 V DC Maximum input voltage: 180 V DC to 300 V DC Rated current: 6.5 A Power port type: C14 |
| Temperature | Operating temperature: 0°C to 40°C (32°F to 104°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
Operating temperature: 0°C to 40°C (32°F to 104°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F) Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation. |
| Humidity | Operating humidity: 10% RH to 90% RH (non-condensing)
Storage humidity: 5% RH to 95% RH (non-condensing) |
Operating humidity: 10% RH to 90% RH (non-condensing)
Storage humidity: 5% RH to 95% RH (non-condensing) |
| Altitude | Operating altitude: ≤ 5,000 m (16,404.20 ft.)
Storage altitude: ≤ 5000 m (16,404.20 ft.) |
Operating altitude: ≤ 5,000 m (16,404.20 ft.)
Storage altitude: ≤ 5000 m (16,404.20 ft.) |
| Cooling | Air cooling, front-to-rear airflow (port-side intake) | Air cooling, front-to-rear airflow (port-side intake) |
Software Specifications
| Item | RG-S6580-48CQ8QC | RG-S6580-24DC8QC |
| Layer 2 Protocols | IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), Jumbo Frame (9 KB) | |
| Layer 3 Protocols (IPv4) | BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, Policy-based Routing (PBR), route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP | |
| IPv6 Basic Protocols | Neighbor Discovery, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS | |
| IPv6 Features | Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+ | |
| Data Center Features | PFC, ECN, and other data center features
RDMA VXLAN bridge VXLAN gateway IPv6 VXLAN over IPv4 IPv4 VXLAN over IPv4 ECN over VXLAN PFC over VXLAN |
|
| Visualization | gRPC
sFlow sampling IPFIX |
|
| QoS | Mapping of IEEE 802.1p, DSCP, and ToS priorities ACL-based traffic classification Priority marking/remarking Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR Congestion avoidance mechanisms such as WRED and tail discarding |
|
| HA Design | GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 1+1 power redundancy and fan redundancy, and hot swapping for all cards and power supply modules | |
| Security Features | Network foundation protection policy (NFPP), CPP, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, broadcast packet suppression, hierarchical user management | |
| Management Mode | SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and temperature alarm | |
| Other Protocols | DHCP client, DHCP relay, DHCP server, DNS client, ARP proxy, and Syslog | |
Order Information
Chassis, Fan Module
| Product Model | Description |
| RG-S6580-48CQ8QC | 48 × 100GE DSFP ports + 8 × 400GE QSFP-DD ports
Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. |
| RG-S6580-24DC8QC | 24 × 200GE QSFP56 ports + 8 × 400GE QSFP-DD ports
Two power slots and six fan slots The chassis is installed with two RG-PA1200I-F modules and six M1HFAN II-F fan modules. |
Power Supply Module
| Product Model | Description |
| RG-PA1200I-F | 1200 W AC module (AC/240 V HVDC) |
Fan Module
| Product Model | Description |
| M1HFAN II-F | Fan module (front-to-rear ventilation) |
100GE Optical Transceivers
| Model | Description |
| 100G-AOC-5M | 100G AOC, QSFP28 form factor, 5 m (16.40 ft.) |
| 100G-AOC-10M | 100G AOC, QSFP28 form factor, 10 m (32.81 ft.) |
| 100G-QSFP-SR-MM850 | 100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over multimode fiber (MMF) |
| 100G-QSFP-iLR4-SM1310 | 100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
| 100G-QSFP-LR4-SM1310 | 100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
| 100G-QSFP-ER4-SM1310 | 100GE ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF |
400GE Optical Transceivers
| Model | Description |
| 400G-QDD-SR8-MM850 | 400G optical transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF |
| 400G-QDD-DR4-SM1310 | 400G optical transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF |
| 400G-QDD-FR4-SM1310 | 400G FR4 module, QSFP-DD form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
| *400G-QDD-ZR-SM1550 | 400G ZR optical transceiver, QSFP-DD, Duplex LC, 1550 nm, 80 km (262,467.19 ft.) over SMF |