RG-S6250-48XS8CQ 10GE Data Center Access Switch

Highlight Features

  • 48 x 1G/10G SFP+ ports and 8 x 40G/100G QSFP28 ports
  • Cross-device link aggregation (De-stacking/M-LAG/VSU), device-level redundancy, flexible networking, and high reliability
  • VXLAN tunneling technology, achieving unlimited data transmission and flexible resource allocation and scheduling
  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication
  • Telemetry/gRPC/sFlow/SPAN-based network monitoring and automated O&M, making management simple and efficient

Key Specification

 

Switching capacity  2.56 Tbps  Packet forwarding rate  1920 Mpps 
Service port  48 x 1G/10G SFP+ ports

8 x 40G/100G QSFP28 ports 

Dimensions (W x D x H)  442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.) 
Operating temperature  0°C to 45°C (32°F to 113°F)  Operating humidity  10% RH to 90% RH (non-condensing) 

 

Features

Data Center 10GE Access Switch RG-S6250-48XS8CQ

10GE high-density access switch with 10GE/100GE downlink ports and 100GE uplink ports backward compatible with 40GE for adaptation to different scenarios

Large buffer and advanced buffer scheduling mechanism, providing fast data processing and easily coping with burst traffic

Cross-device Link Aggregation, Implementing Device-level Redundancy, Flexible Networking, and High Reliability

De-stacking

De-stacking technology logically aggregates multiple switches through LACP to allow servers on the same network segment or on different network segments to communicate. This eliminates the need to synchronize data between switches, without affecting service transmission.

M-LAG

M-LAG technology implements load sharing between links and improves link reliability. The independent control plane supports independent device upgrade, realizing service upgrade within seconds and consistent user experience.

VSU

VSU technology can virtualize multiple physical devices into one logical device, simplifying network configuration and architecture, eliminating loops, and improving reliability.

PFC- and ECN-based Lossless Ethernet with High Throughput and Low Latency in RDMA Scenarios

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden

and effectively solves the network latency problem.

PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M, Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy.

The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time, making network management more efficient and accurate.

 

Specifications

Hardware Specifications

Item RG-S6250-48XS8CQ
Dimensions (W x D x H) 442 mm x 387 mm x 44 mm (17.40 in. x 15.24 in. x 1.73 in.)
Rack height 1 RU
Unit weight 5.6 kg (12.35 lbs., empty chassis)

8.2 kg (18.08 lbs., a chassis installed with two power modules and four fan modules)

Switching capacity 2.56 Tbps
Packet forwarding rate 1920 Mpps
Service port 48 x 1G/10G SFP+ ports

8 x 40G/100G QSFP28 ports

Management port 1 x RJ45 console port

1 x RJ45 MGMT port

USB port 1 x USB 2.0 port (Type A connector)
Module slot 2 x power module slots

4 x fan module slots

Power consumption Maximum power consumption: 300 W

Typical power consumption: 165 W

Static power consumption: 98 W

Power input RG-PA550I-F (AC input):

Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 140 V AC, 180 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current: 7.2 A to 3.5 A (100 V AC to 240 V AC)

Power port type: C14

 

RG-PA550I-F (HVDC input):

Rated input voltage: 240 V DC

Maximum input voltage: 180 V DC to 310 V DC

Rated current: 3.6 A

Power port type: C14

 

RG-PHD550I-F (AC input):

Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz

Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz

Rated input current: 10 A

Power port type: C14

 

RG-PHD550I-F (HVDC input):

Rated input voltage: 336 V DC

Maximum input voltage: 160 V DC to 400 V DC

Rated input current: 10 A

Power port type: C14

 

RG-PD800I-F (DC input):

Rated input voltage: –48 V DC

Maximum input voltage: –36 V DC to –72 V DC

Rated input current: 23 A

Power port: three-pin power port

Temperature Operating temperature: 0°C to 45°C (32°F to 113°F)

Storage temperature: –40°C to +70°C (–40°F to +158°F)

Note: At altitudes ranging from 1800 m (5,905.51 ft.) to 5000 m (16,404.20 ft.), the maximum temperature decreases by 1°C (1.8°F) for every 200 m (656.17 ft.) increase in elevation.

Humidity Operating humidity: 10% RH to 90% RH (non-condensing)

Storage humidity: 5% RH to 95% RH (non-condensing)

Altitude Operating altitude: ≤ 5,000 m (16,404.20 ft.)

Storage altitude: ≤ 5000 m (16,404.20 ft.)

Cooling Air cooling, front-to-rear airflow (port-side intake)

 

Software Specifications

Item RG-S6250-48XS8CQ
Layer 2 protocols IEEE802.3ae (10GBase), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (static link aggregation, LACP, M-LAG), IEEE802.1p, IEEE802.1Q,

IEEE802.1D (STP), STP root guard, and BPDU guard

IEEE802.1w(RSTP), IEEE802.1s(MSTP)

IGMP Snooping v1/v2, MLD Snooping, Jumbo Frame(9Kbytes)

IEEE 802.1ad (QinQ and selective QinQ), GVRP, Three modes (access, trunk, and hybrid), LLDP, static MAC address, MAC address filtering, MAC address quantity limit

N/A
Layer 3 protocols (IPv4) Static routing, BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM routing, policy-based routing (PBR), route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, and Any-RP, BFD for BGP/IS-IS/OSPF/static routing, manual tunnel, GRE tunnel
Basic IPv6 protocols Neighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, IS-ISv6, ACLv6, IPv6 TCP/UDP, SNMPv6, IPv6 Ping/Traceroute, IPv6 RADIUS, IPv6 Telnet/SSH, IPv6 FTP/TFTP, NTPv6, IPv6 MIB for SNMP, IPv6 VRRP, IPv6 QoS
IPv6 features Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+, IS-ISv6, IPv6 VRRP, MLDv1/v2, PIM-SMv6, manual tunnel, GRE tunnel, automatic tunnel, IPv4 over IPv6 tunnel, and ISATAP tunnel
Data center features VXLAN routing and VXLAN bridging

EVPN VXLAN

VXLAN mapping

IPv4 VXLAN over IPv4

IPv6 VXLAN over IPv4

IPv6 VXLAN over IPv6

IPv6 VXLAN over IPv6

VXLAN over IPv6

M-LAG

OpenFlow 1.3

RDMA, RoCEv2, PFC, and ECN

Process gRPC

sFlow sampling

IPFIX sampling

QoS IEEE 802.1p, ToS, and DSCP priority mapping

ACL traffic classifier, and priority tagging Mark/Remark

Various queue scheduling mechanisms such as SP (PQ), WRR, DRR, SP (PQ)+WRR, and SP (PQ)+DRR

Flexible queue scheduling algorithms based on ports or queues

Congestion avoidance mechanisms such as WRED and tail discarding

Ingress/egress port-based rate limiting and CAR

MPLS MPLS VPN
Virtualization Virtual switching unit (VSU)
Buffer management Buffer usage monitoring and traffic microburst detection
High availability GR for RIP/OSPF/BGP, BFD, DLDP, VRRP, VRRP load balancing/dual-active, BFD for VRRP, REUP, RLDP, 1+1 power redundancy and fan redundancy, and hot swappable line cards and power modules
Security features Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), DDoS/DoS attack defense, ICMP attack defense, unauthorized packet detection, data encryption, source IP spoofing defense, IP scanning attack defense, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL, port-based ACL, or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, uRPF, broadcast packet suppression, DHCP snooping, ARP spoofing defense (ARP anti-spoofing), ARP check, and hierarchical user management
Management mode SNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, NETCONF, Python, fan and power alarm, temperature alarm, and configuration rollback
Other protocols DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP Relay, Proxy ARP, and Syslog

 

Order Information

Chassis

Model Description
RG-S6250-48XS8CQ RG-S6250-48XS8CQ chassis, 48 x 10GE SFP+ ports, 8 x 100GE QSFP28 ports, 2 x power module slots, 4 x fan module slots. The chassis is equipped with two power modules (RG-PA550I-F) and four fan modules (M1EFAN II-F).

 

Power Modules

Model Description
RG-PA550I-F 550 W power module (supporting AC and 240 V HVDC)
RG-PD800I-F 800 W power module (supporting 48 V LVDC) for the RG-S6250-48XS8CQ and the RG-S6510-48VS8CQ
RG-PA550I-R 550 W AC power module (rear-to-front airflow, supporting AC and 240 V HVDC), used with rear-to-front airflow fan module M1EFAN IV-R
RG-PHD550I-F 550 W AC power module (supporting 336 V HVDC)

 

Fan Modules

Model Description
M1EFAN II-F Fan module (port-side intake) for the RG-S6250-48XS8CQ
M1EFAN III-F Fan module (port-side intake) for the RG-S6231-48XT8CQ, the RG-S6231-48XS8CQ, the RG-S6232-48XS8CQ, and the RG-S6501-48VS8CQ
M1EFAN IV-R Fan module (fan-side intake), applicable to the RG-S6231-48XS8CQ and the RG-S6231-48XT8CQ

 

40G Optical Transceivers

Model Description
40G-AOC-5M 40G QSFP+ active optical cable (AOC), 5 m (16.40 ft.)
40G-AOC-30M 40G QSFP+ active optical cable, 30 m (98.43 ft.)
40G-QSFP-SR-MM850 40G SR optical transceiver, QSFP+ form factor, MPO, 150 m (492.13 ft.) over multimode fiber (MMF)
40G-QSFP-LSR-MM850 40G SR optical transceiver, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF
40G-QSFP-LR4-SM1310 40G LR4 optical transceiver, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over single-mode fiber (SMF)
40G-QSFP-iLR4-SM1310 40G iLR4 optical transceiver, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF
40G-QSFP-LX4-SM1310 40G LX4 optical transceiver, QSFP+ form factor, Duplex LC, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF


100G Optical Transceivers

Model Description
100G-AOC-5M 100G AOC, QSFP28 form factor, 5 m (16.40 ft.)
100G-AOC-10M 100G AOC, QSFP28 form factor, 10 m (32.81 ft.)
100G-QSFP-SR-MM850 100G SR optical transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF
100G-QSFP-iLR4-SM1310 100G iLR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF
100G-QSFP-LR4-SM1310 100G LR4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF
100G-QSFP-ER4-SM1310 100G ER4 optical transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.60 ft.) over SMF

 

GE Optical Transceivers

Model Description
GE-SFP-LH40-SM1310-BIDI 1G LH optical transceiver, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF
GE-SFP-LX20-SM1310-BIDI 1G LX optical transceiver, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF
GE-SFP-LX20-SM1550-BIDI 1G LX optical transceiver, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF
MINI-GBIC-LH40-SM1310 1G LH optical transceiver, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF
MINI-GBIC-LX-SM1310 1G LX optical transceiver, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF
MINI-GBIC-SX-MM850 1G SR optical transceiver, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF
MINI-GBIC-ZX80-SM1550 1G ZX optical transceiver, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF

 

GE Copper Transceivers

Model Description
Mini-GBIC-GT(F) 1G copper transceiver, SFP form factor, RJ45, used with Cat5e, Cat 6, and Cat6a, transmission distance of up to 100 m (328.08 ft.) For the RG-S6200 series products, the Mini-GBIC-GT(F) transceiver is applicable only to the RG-S6250-48XS8CQ.
Mini-GBIC-GT 1G copper transceiver, SFP form factor, RJ45, used with Cat5e, Cat 6, and Cat6a, transmission distance of up to 100 m (328.08 ft.)

 

10GE Optical Transceivers

Model Description
XG-SFP-SR-MM850 10G SR optical transceiver, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF
XG-SFP-LR-SM1310 10G LR optical transceiver, SFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF
XG-SFP-ER-SM1550 10G ER optical transceiver, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF
XG-SFP-ZR-SM1550 10G ZR optical transceiver, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF
XG-LR-SM1310 10G LR optical transceiver, SFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF
XG-SFP-AOC1M 10G AOC, SFP+ form factor, 1 m (3.28 ft.)
XG-SFP-AOC3M 10G AOC, SFP+ form factor, 3 m (9.84 ft.)
XG-SFP-AOC5M 10G AOC, SFP+ form factor, 5 m (16.40 ft.)
XG-SR-MM850 10G SR optical transceiver, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF

 

Models

RG-S6250-48XS8CQ

Series

RG-S6200 Series